DVI Converter
ODC-10000
4.

How to configure DVI Converter control mode

4-1.

RS-232C Interface mode

1.
RS-232C Mode configuration
x
Serial communication applies RS-232C standard.
x
If the LED on "CTRL_SET" Button in the front is turned on, RS-232C command is not
working. Press "CTRL_SET" Button and the LED is turned off, RS-232C command is
executed.
x
Ethernet mode is not available during RS-232C mode.
x
It can be controlled through a serial port of MSCS (Multi Screen Control Software.)
2.
Communication configuration
Transmission Type
Asynchronous Serial Communication
Baud Rate
115200bps
* When the LED on "CTRL_SET" Button in the front is turned off, RS-232C communication
mode is working.
The other communication modes are not available besides Key.
3.
Connection Diagram
RS-232C
RS-232C
IN
OUT
DVI Converter
RS-232C Distributor
PC (Controller)
RS-232C
PC (Controller)
IN
DVI Converter
8
| ORION PDP CO., LTD.
Parity bit
None
Stop bits
1
PDP 1
PDP
PDP
PDP
2
N-1
N
IN
OUT
IN
OUT
IN
OUT
IN
OUT
RS-232C
PDP 1
PDP
PDP
PDP
2
N-1
N
IN
OUT
IN
OUT
IN
OUT
IN
OUT
PDP 1
PDP
PDP
PDP
2
N-1
N
IN
OUT
IN
OUT
IN
OUT
IN
OUT
PDP 1
PDP
PDP
PDP
2
N-1
N
OUT
IN
OUT
IN
OUT
IN
OUT
IN
4-2.

Ethernet Interface mode

1.
Ethernet Mode configuration
x
Ethernet communication is based on TCP/IP Protocol. According to DHCP configuration,
it can be used as dynamic or static IP. Remote control is also available via World Wide
Web.
x
If the LED on "CTRL_SET" Button in the front is turned off, Ethernet command is not
working. Press "CTRL_SET" Button and the LED is turned on, Ethernet mode is activated
and its command is executed.
x
RS-232C mode is not available during Ethernet mode.
x
It can be controlled through a LAN port of MSCS (Multi Screen Control Software.)
x
To use Ethernet mode, Ethernet is configured at Configuration mode in advance.
x
Perform Ping test to check the connection status after configuration.
If "Request timed out" response lasts more than 5 minutes, check the Ethernet
configuration.
If the problem continues, contact to your server manager. (H/W Port Number: 9761)
Ping Test
The window as shown in the left side of the following pictures is popped up by pressing
"Window" key and "R" key at the same time. Type the IP address in the window.
e.g. "Ping 192.168.10.248 -t"
Then the DOS window is open and ping test start. (Ping test can be done at DOS window)