DVI Converter
ODC-10000
-
"Tracking Mode" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Tracking Mode Command transmission (to Ch2)
Tracking Mode Command transmission (to Ch1)
*"Get Tracking Values" command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Get Tracking Mode Command transmission (to Ch2)
Get Tracking Mode Command transmission (to Ch1)
3.15.
Default Data Load (Picture Control Data)
-
The command for initializing the adjusted values and apply the built-in values.
-
It is available only during Power on status.
-
This commands should be executed with care, because all the adjusted values will be erased.
-
Send to MPDP
STX
CMD
Length
Value
0x02
0x97
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0x97
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
54
| ORION PDP CO., LTD.
→
Tracking Mode Response transmission (from Ch2)
←
→
Tracking Mode Response transmission (from Ch1)
←
→
Get Tracking Mode Response transmission (from Ch2)
←
→
Get Tracking Mode Response transmission (from Ch1)
←
Data
ETX
ID
Ch1/Ch2
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
-
"Default Data Load" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Default Data Load Command transmission (to Ch2)
Default Data Load Command transmission (to Ch1)
3.16.
Graphic User Mode Control
-
The command for adjusting the values of Brightness, Contrast, Sharpness, Color, and Tint.
-
CMD: 0x8F (Brightness), 0x90 (Contrast), 0x91 (Sharpness), 0x92 (Color), 0x93 (Tint)
-
It is available only during Power on status.
-
The adjusted value will not be applied during stand-by phase or no input signal.
So, there must be input signals of corresponding mode to apply adjusted values.
-
Send to MPDP
STX
CMD
Length
Value
0x02
Variable
0x03
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Value:
x
Brightness ("0" ~ "100"), Contrast ("0" ~ "100"), Sharpness ("0" ~ "28"), Color ("0" ~ "100"), Tint ("0" ~ "100")
-
Receive from MPDP
STX
CMD
Length
Value
0x02
Variable
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
-
"Graphic User Mode Control" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Infinitely Expandable
→
Default Data Load Response transmission (from Ch2)
←
→
Default Data Load Response transmission (from Ch1)
←
Data
ETX
ID
Ch1/Ch2
Value
Variable
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
ORION PDP CO., LTD. |