DVI Converter
ODC-10000
-
"Tracking Mode" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Tracking Mode Command transmission (to Ch2)
Tracking Mode Command transmission (to Ch1)
*"Get Tracking Values" command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Get Tracking Mode Command transmission (to Ch2)
Get Tracking Mode Command transmission (to Ch1)
3.15.
Default Data Load (Picture Control Data)
-
The command for initializing the adjusted values and apply the built-in values.
-
It is available only during Power on status.
-
This commands should be executed with care, because all the adjusted values will be erased.
-
Send to MPDP
STX
CMD
Length
Value
0x02
0x97
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0x97
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
54
| ORION PDP CO., LTD.
Tracking Mode Response transmission (from Ch2)
Tracking Mode Response transmission (from Ch1)
Get Tracking Mode Response transmission (from Ch2)
Get Tracking Mode Response transmission (from Ch1)
Data
ETX
ID
Ch1/Ch2
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
-
"Default Data Load" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Default Data Load Command transmission (to Ch2)
Default Data Load Command transmission (to Ch1)
3.16.
Graphic User Mode Control
-
The command for adjusting the values of Brightness, Contrast, Sharpness, Color, and Tint.
-
CMD: 0x8F (Brightness), 0x90 (Contrast), 0x91 (Sharpness), 0x92 (Color), 0x93 (Tint)
-
It is available only during Power on status.
-
The adjusted value will not be applied during stand-by phase or no input signal.
So, there must be input signals of corresponding mode to apply adjusted values.
-
Send to MPDP
STX
CMD
Length
Value
0x02
Variable
0x03
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Value:
x
Brightness ("0" ~ "100"), Contrast ("0" ~ "100"), Sharpness ("0" ~ "28"), Color ("0" ~ "100"), Tint ("0" ~ "100")
-
Receive from MPDP
STX
CMD
Length
Value
0x02
Variable
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
-
"Graphic User Mode Control" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Infinitely Expandable
Default Data Load Response transmission (from Ch2)
Default Data Load Response transmission (from Ch1)
Data
ETX
ID
Ch1/Ch2
Value
Variable
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03