DVI Converter
ODC-10000
2.2.
Receive From DVI Converter
STX
CMD
Length
1 byte
1 byte
1 byte
ID
1 byte
-
It is a format to respond to certain commands. The difference from "Send to PDP" is the existence of "Check Sum".
-
STX (0x02): The initiation Code. The beginning of Protocol. (Fixed value)
-
Command: The code of actual execution (Dynamic value)
-
Length: The length of "Data" area. (Dynamic value: "0"~"255")
-
Data: "ID," "Ch1/Ch2" and other Data area (Dynamic value)
-
ID: The code to distinguish DVI Converter. It is allocated in the rage of "101"~"109."
-
Ch1/Ch2: The classification code for "Channel1" is "0x01", "Channel2" for "0x00." (Dynamic value)
-
Check Sum: Add all the values of "STX~Data" and execute "Not" operation.
-
ETX (0x03): The end of Protocol. (Fixed value)
3.
Command
3.1.
Infomation
-
Display information on the DVI Converter screen. (Input source and resolution by OSD)
-
It is available only during Power on status.
Send to MPDP
-
STX
CMD
Length
Value
0x02
0x42
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Ch1 (0x01), Ch2 (0x00)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0x42
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
-
"Information" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
42
| ORION PDP CO., LTD.
Data
Check Sum
ETX
Variable
1 byte
1 byte
Ch1/Ch2
Other Data
1 byte
N byte
Data
ETX
ID
Ch1/Ch2
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
Information Command transmission (to Ch2)
Information Command transmission (to Ch1)
3.2.
Input-Mode Change
-
Change input mode without screen scaling.
-
It is available only during Power on status.
-
CMD: 0xA4 (DVI ), 0xA5 (HDMI), 0xA6 (HDSDI), 0xA7 (PC), 0xA8 (DTV), 0xAA (S-VIDEO), 0xAB (VIDEO)
-
Send to MPDP
STX
CMD
Length
Value
0x02
Variable
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
Variable
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
-
"Input-Mode Change" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Input-Mode Change Command transmission (to Ch2)
Input-Mode Change Command transmission (to Ch1)
Infinitely Expandable
Information Response transmission (from Ch2)
Information Response transmission (from Ch1)
Data
ETX
ID
Ch1/Ch2
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
Input-Mode Change Response transmission (from Ch2)
Input-Mode Change Response transmission (from Ch1)