Test Pattern - Orion ODC-10000 User Manual

Dvi converter
Hide thumbs Also See for ODC-10000:
Table of Contents

Advertisement

DVI Converter
ODC-10000
3.3.

Test Pattern

-
Checking the image quality of DVI Converter with the built-in pattern
-
It is available only during Power on status.
-
Send to MPDP
STX
CMD
Length
Value
0x02
0x96
0x03
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Value:
x
Screen (0x01), White (0x02), Red (0x03), Green (0x04), Blue (0x05), 8-Color (0x06), 10%-White (0x07),
16-Gray (0x08)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0x96
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
-
"Test Pattern" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Test Pattern Command transmission (to Ch2)
Test Pattern Command transmission (to Ch1)
3.4.
Key Lock Mode
-
The command for restricting Front Key function of DVI Converter
-
It is available only during Power on status.
-
Send to MPDP
STX
CMD
Length
Value
0x02
0x5C
0x03
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
44
| ORION PDP CO., LTD.
Data
ETX
ID
Ch1/Ch2
Value
Variable
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
Test Pattern Response transmission (from Ch2)
Test Pattern Response transmission (from Ch1)
Data
ETX
ID
Ch1/Ch2
Value
Variable
Variable
Variable
0x03
* Value: Key Lock Mode On (0x01), Key Lock Mode Off (0x02)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0x5C
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
-
"Key Lock Mode" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Key Lock Mode Command transmission (to Ch2)
Key Lock Mode Command transmission (to Ch1)
3.5.
PIP Mode
-
The command for PIP function of DVI Converter
-
It is available only during Power on status.
-
Send to MPDP
STX
CMD
Length
Value
0x02
0x98
0x03
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Value: Normal (0x01), PIP Mode (0x02)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0x98
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
-
"PIP Mode" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
Infinitely Expandable
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
Key Lock Mode Response transmission (from Ch2)
Key Lock Mode Response transmission (from Ch1)
Data
ETX
ID
Ch1/Ch2
Value
Variable
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
ORION PDP CO., LTD. |
45