DVI Converter
ODC-10000
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0xA2
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
"Output Resolution Change" Communication Sequence
-
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Output Resolution Change Command transmission (to Ch2)
Output Resolution Change Command transmission (to Ch1)
3.11.
Get Test Pattern Status
-
The command for checking Test Pattern information.
-
It is available only during Power on status.
-
Send to MPDP
STX
CMD
Length
Value
0x02
0x60
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0x60
0x3
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
* Status
Screen (0x01), White (0x02), Red (0x03), Green (0x04), Blue (0x05), 8-Color (0x06), 10%-White (0x07),
16-Gray (0x08)
50
| ORION PDP CO., LTD.
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
Output Resolution Change Responsetransmission (from Ch2)
Output Resolution Change Response transmission (from Ch1)
Data
ETX
ID
Ch1/Ch2
Variable
Variable
0x03
Data
Check
ETX
Sum
ID
Ch1/Ch2
Status
Variable
Variable
Variable
Variable
0x03
-
"Test Pattern Status Get" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Test Pattern Status Get Command transmission (to Ch2)
Test Pattern Status Get Command transmission (to Ch1)
3.12.
Auto-Calibration
-
The command for adjusting Gain and Offset of ADC with 100% 8-Color input. It is available only for PC/DTV input.
-
It is available only during Power on status.
-
Send to MPDP
STX
CMD
Length
Value
0x02
0x80
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0x80
0x03
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
-
"Auto-Calibration" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Auto-Calibration Command transmission (to Ch2)
Auto-Calibration Command transmission (to Ch1)
Infinitely Expandable
Test Pattern Status Get Response transmission (from Ch2)
Test Pattern Status Get Response transmission (from Ch1)
Data
ETX
ID
Ch1/Ch2
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
Auto-Calibration Response transmission (from Ch2)
Auto-Calibration Response transmission (from Ch1)
ORION PDP CO., LTD. |
51

Advertisement

Table of Contents
loading

Table of Contents