Orion ODC-10000 User Manual page 25

Dvi converter
Hide thumbs Also See for ODC-10000:
Table of Contents

Advertisement

DVI Converter
ODC-10000
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
PIP Mode Command transmission (to Ch2)
PIP Mode Command transmission (to Ch1)
3.6.
PIP Position
-
The command for controlling the PIP screen position
-
It is available only during Power on status.
-
CMD: 0x5D ( PIP H. Position), 0x5E (PIP V. Position)
-
Send to MPDP
STX
CMD
Length
Value
0x02
Variable
0x03
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Value:
x
PIP H. Position: 0 (0x00) ~ 100 (0x64)
x
PIP V. Position: 0 (0x00) ~ 100 (0x64)
Receive from MPDP
-
STX
CMD
Length
Value
0x02
Variable
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
-
"PIP Position" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
PIP Position Command transmission (to Ch2)
PIP Position Command transmission (to Ch1)
46
| ORION PDP CO., LTD.
PIP Mode Response transmission (from Ch2)
PIP Mode Response transmission (from Ch1)
Data
ETX
ID
Ch1/Ch2
Value
Variable
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
PIP Position Response transmission (from Ch2)
PIP Position Response transmission (from Ch1)
3.7.
PIP Swap Mode
-
The command for interchanging the positions of main picture and sub picture.
-
It is available only for PIP mode during Power on status.
-
Send to MPDP
STX
CMD
Length
Value
0x02
0x99
0x03
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Value:
x
Normal Mode (0x01) - Main picture and Sub picture are displayed without position change.
x
Swap Mode (0x02) - The positions of Main picture and Sub picture are interchanged.
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0x99
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
-
"PIP Swap" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
PIP Swap Command transmission (to Ch2)
PIP Swap Command transmission (to Ch1)
3.8.
PIP Input-Mode Change
-
The command for changing PIP Input mode without screen scaling.
-
It is available only for PIP mode during Power on status.
Infinitely Expandable
Data
ETX
ID
Ch1/Ch2
Value
Variable
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
PIP Swap Response transmission (from Ch2)
PIP Swap Response transmission (from Ch1)
ORION PDP CO., LTD. |
47

Advertisement

Table of Contents
loading

Table of Contents