Orion ODC-10000 User Manual page 26

Dvi converter
Hide thumbs Also See for ODC-10000:
Table of Contents

Advertisement

DVI Converter
ODC-10000
-
Send to MPDP
STX
CMD
Length
Value
0x02
0xA0
0x03
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2 : Channel1 (0x01), Channel2 (0x00)
* Value
x
DVI (0x01), HDMI (0x02), HDSDI (0x03), PC (0x04), DTV (0x05), S-VIDEO (0x06), VIDEO (0x07)
x
If the Main Input-Mode is DVI, HDMI, or HDSDI, PIP Input-Mode cannot be DVI, HDMI, or HDSDI.
x
If the Main Input-Mode is PC, DTV, S-VIDEO, or VIDEO, PIP Input-Mode cannot be PC, DTV, S-VIDEO, or
VIDEO.
x
Main Input-Mode and PIP Input-Mode cannot have the same input source.
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0xA0
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
-
"Input-Mode Change" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1).
Input-Mode Change Command transmission (to Ch2)
Input-Mode Change Command transmission (to Ch1)
3.9.
Get PIP Status
-
The command for checking PIP status information.
-
It is available only during Power on status.
-
CMD: 0x5F
-
Send to MPDP
STX
CMD
Length
Value
0x02
0x5F
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
48
| ORION PDP CO., LTD.
Data
ETX
ID
Ch1/Ch2
Value
Variable
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
Input-Mode Change Response transmission (from Ch2)
Input-Mode Change Response transmission (from Ch1)
Data
ETX
ID
Ch1/Ch2
Variable
Variable
0x03
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0x5F
0x07
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
* Status
No.
Data
Length
1
PIP Mode
1 byte
2
PIP H. Position
1 byte
3
PIP V. Position
1 byte
4
PIP Input Source
1 byte
5
PIP Swap Mode
1 byte
-
"PIP Status Get" Communication Sequence
* Wait for the response for 40msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
PIP Status Get Command transmission (to Ch2)
PIP Status Get Command transmission (to Ch1)
3.10.
Output Resolution Change
-
The command for changing the output resolution of DVI Converter
-
It is available only for PIP mode during Power on status. In case of PIP mode, it becomes PIP Normal mode.
-
Send to MPDP
STX
CMD
Length
Value
0x02
0xA2
0x03
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Value
x
640x480(60Hz) (0x01), 640x480(85Hz) (0x02), 800x600(50Hz) (0x03), 800x600(60Hz) (0x04),
800x600(85Hz) (0x05), 853x480(50Hz) (0x06), 853x480(60Hz) (0x07), 1024x768(60Hz) (0x08),
1024x768(85Hz) (0x09), 1280x1024(50Hz)(0x0A), 1280x1024(60Hz) (0x0B), 1600x900(50Hz) (0x0C),
1600x900(60Hz) (0x0D), 1600x1200(50Hz) (0x0E), 1600x1200(60Hz) (0x0F), 1706x960(60Hz) (0x10),
1080P(50Hz)(0x11), 1080P(60Hz)(0x12)
Infinitely Expandable
Data
Check
ETX
Sum
ID
Ch1/Ch2
Status
Variable
Variable
...
Variable
0x03
Explanation
1:Normal, 2: PIP
0 (0x00) ~ 100 (0x64)
0 (0x00) ~ 100 (0x64)
1: DVI, 2: HDMI, 3: HDSDI, 4: PC, 5: DTV, 6: S-Video, 7: Video
1: Normal, 2: Swap
PIP Status Get Response transmission (from Ch2)
PIP Status Get Response transmission (from Ch1)
Data
ETX
ID
Ch1/Ch2
Value
Variable
Variable
Variable
0x03
ORION PDP CO., LTD. |
49