Orion ODC-10000 User Manual

Video wall displays, infinitely expandable
Hide thumbs Also See for ODC-10000:

Advertisement

Quick Links

MLCD
A revolutionary MLCD
A revolutionary MLCD
Infinitely Expandable
Infinitely Expandable MLCD
ORION PDP CO.,LTD.
www.oriondisplay.net
Address: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea
Tel : +82-2-6678-8533,
Fax: +82-2-6678-8599
User's Manual
OLM-5550
Thank you for purchasing our MLCD.
Please read through this user's manual for safety before installing this product.
This product is manufactured for Multi LCD model only.

Advertisement

Table of Contents
loading

Summary of Contents for Orion ODC-10000

  • Page 1 MLCD A revolutionary MLCD A revolutionary MLCD Infinitely Expandable Infinitely Expandable MLCD ORION PDP CO.,LTD. www.oriondisplay.net Address: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea Tel : +82-2-6678-8533, Fax: +82-2-6678-8599 User’s Manual OLM-5550 Thank you for purchasing our MLCD. Please read through this user's manual for safety before installing this product.
  • Page 2 DVI Converter RS-232C Distributor New MFC SET moisture, does not operate normally, or has been dropped. (refer to page 12~13) (ODC-10000) Necessaryforconnectingmore The symbol in figure 21 shall be shown adjacent to the text of item 12 above. than20units. MPDP...
  • Page 3: Table Of Contents

    MLCD Infinitely Expandable ORION PDP Contents ※Cautions for consisting MLCD System  ...................4 CAUTION ※ Please keep following instruction for panel protection without exception.  ..6 ※Handle with Caution. ..........................7 RISK OF ELECTRIC SHOCK 1. Safety Precautions DO NOT OPEN  .
  • Page 4: Cautions For Consisting Mlcd System

    MLCD Infinitely Expandable ORION PDP ※Cautions for consisting MLCD System The number of Daisy chain connection Environmental condition for installation - S inceMLCDpanelisverysensitiveforphysicalimpact,installationrequires - T heimagequalitymayvarydependonthequalityofsignalandcablecondition. considerablecaution. INPUT SOURCE Resolution Connection Remark - M inimumclearance(20cm)mustbesecuredforsmoothventilation.(SeeP12~13) 1600x1200x60Hz 6sets Installationmustavoidairtightornearairtightplaces.Improperventilationcauses 1600x1200x60Hz 3sets malfunctionandshortensproductlifetimebyrapidinternaltemperaturerise.If...
  • Page 5: Please Keep Following Instruction For Panel Protection Without Exception

    MLCD Infinitely Expandable ORION PDP ※ Please keep following instruction ※Handle with Caution. for panel protection without - Shock/Impact on the set's sides will result in exception. internal circuit damages. - The edge/bottom of the panel are fragile. Warning Warning...
  • Page 6: How To Carry Mlcd

    MLCD Infinitely Expandable ORION PDP How to carry MLCD It always needs two persons to carry or install MLCD. When you carry MLCD with flatbed manner, please hold handles on the back and When you carry MLCD with up straight manner, please hold handles on the back lower part of the back.
  • Page 7: Safety Precautions

    MLCD Infinitely Expandable ORION PDP Safety Precautions • If it operates abnormally, stop using it • Do not place any liquid-containing • Do not pull out or hang down the • Do not lean against the product or keep •...
  • Page 8: How To Install

    MLCD Infinitely Expandable ORION PDP How to Install Main FraME Stand Unit (Option) Main FraME Wall Mounting Unit (Option) Pleasedonotinstallourproductatfollowinglocationstoprotecttheproductand Pleasecheckthe stabilityofwall. preventpossiblemalfunction. Ifthewallisnotstrongenough,reinforcethewallbeforeinstallation. -Placesofvibrationorshock:LCDsetmayfallanddamaged - N extorneartoSprinklersensors:Thesensorsmaydetectheatfromasetandsprinklercanbeactivated. Pleaseconnectallthecablestoproperportsinasetbeforeinstallation. -Aroundhighvoltagepowerlines:Noisefromthepowerlinemayaffectscreenimages -Aroundheatingapparatus:LCDsetmaybeoverheatedanddamaged. Thesetcanbeinstalledasshownbelow. Thesetcanbeinstalledonthewallasshownbelow. (Forfurtherinformation,refertotheoptional'MAINFRAMEInstallationandSetupGuide'.) (Forfurtherinformation,refertotheoptional'MAINFRAMEInstallationandSetupGuide'.) MAIN MAIN Hanger FRAME Hanger...
  • Page 9: Guidance For Users

    MLCD Infinitely Expandable ORION PDP Guidance for Users input/Output Terminals Set iD Switch Setting ExampleofIDSwitchsetting - Y oucansetIDwith3rotaryswitchesasshowninthefollowingfigure. [MLCD ID 01] MLCD ID SELECT MLCD VIDEO 100digit10digitsingledigit DVI-D ID SELECT RS-232C VIDEO DVI-D [MLCD ID 15] RS-232C 100digit10digitsingledigit 1.PC In / Out ➊...
  • Page 10: How To Connect Cables

    MLCD Infinitely Expandable ORION PDP How to Connect Cables Donotconnect/disconnectcableswhileMLCDorotherexternalequipmentsareturnedon. Firstturnoffthepoweralltheattachedequipmentandmakeconnections. 4.1. Connection of Single MLCD MLCD MLCDandPCshouldbeconnected;aComPortinaPCandRS-232CINportina MLCDisconnectedwithsuppliedRS-232Ccable. ID SELECT  M LCDOn/OfforScreenadjustmentcanbecontrolledbyMSCS(Multi-ScreenControl System).  I DsettingonthebacksideofMLCDmustbeidenticalwiththeIDsettinginMSCStocontrol MLCDwithaPC. [MLCD ID 1] IfyoudonothaveComPort,youneedtouseanUSBconverterforRS-232C.Depending  I DswitchmustbesetasID1 onmanufacturersormodels,convertersmaycausemalfunction. foronesetuse. Videoconnection (Maximum5m)
  • Page 11: ConnectionOfMultipleMlcd

    MLCD Infinitely Expandable ORION PDP 4.2. Connection of Multiple MLCD RecommendedmaximumsetconnectionforMultisettingisshownintablebelow. Ifyouneedtoconnectmorethandescribedinthetable,youhavetousedistributors. Imagequalitycanbeaffectedbycableorsignalquality. INPUT SOURCE Resolution Connection Remark 1600x1200x60HZ 6sets 1600x1200x60Hz 3sets VIDEO NTST,PAL,SECAM 6sets RS-232C 30sets ORIONCableOnly VIDEO VIDEO VIDEO VIDEO VIDEO DVI-D DVI-D DVI-D DVI-D DVI-D ID SELECT...
  • Page 12: ConnectionOfRs-232CCable

    MLCD Infinitely Expandable ORION PDP 4.3. Connection of rS-232C Cable 4.4. Connection of DVi cable MaximumuseofRS-232CwithDaisyChainconnectionis orless. Ifyouneedadditionalconnection,useRS-232Cdistributor. DVI-D DVI-D DVI-D RS-232C RS-232C RS-232C ID 1 ID 2 ID 3 RS-232C RS-232C RS-232C RS-232C RS-232C ID 1 ID 2 ID 3...
  • Page 13: ConnentionOfOptionalAccessory

    MLCD Infinitely Expandable ORION PDP 4.5. Connention of optional accessory 4.6. iD setting of X x Y MLCD [MLCD ID 01] Identitynumber(ID)indicatesthelocationofeachMLCD. WhenyoulookattheMLCDscreensinfrontofMLCD. 100digit10digitsingledigit RS-232C DVI-D RS-232C DVI-D RS-232C DVI-D LCD ID LCD ID LCD ID LCD ID LCD ID...
  • Page 14: Setting And Operation Of Mscs Software

    MLCD Infinitely Expandable ORION PDP Setting and operation of MSCS software 5.1. MSCS installation 5.2. Start MSCS InserttheInstallationCD. MSCSisanapplicationprogramneededtocontrolMLCD. Youcanseefollowinginstallationstartscreen. WhenyouexecuteMSCS(v5.1)foryourproductattheinstallationscreen,itwillcreatea newfolderat C:/ProgramFile/MSCS(v5.1) andanicononyourcomputerscreen. Selectproperversionforyourproductandstartinstallation BydoubleclickingtheMSCS(v )icon,theinitialscreenimageofMSCS(v willbedisplayedasshowninthepicture. ® 2000, Windows® XP and Windows Vista™ only MSCS supports Windows MSCSInstallationstartscreen.
  • Page 15: SettingOfComPort

    MLCD Infinitely Expandable ORION PDP 5.3. Setting of COM Port 5.4. Setting of Lan Port ComPortconnectsordisconnectsthecommunicationbetweenPCandMLCD. ThisfunctionisusedtocontroltheMLCDviaLANPORT. ConnectMLCDtoPCComPortviaRS-232Ccable. *ConnectMLCDtoPCComPortviaRS-232Ccable. *ConnectMLCDtoPCLANPortviaLANcable. Network IP setting for MLCD 1)ExecutethePIC(forOLM-4610,OPM-4260)cfg.exe 2)SelectComPortandselect"OPEN". GotoMSCSMenu→CommunicationandsetComPort.Click'Connect'usingmouseor press'Ctrl+C'usingkeyboard.  I nordertodisconnectcommunication,click'Disconnect'usingmouseorpress'Ctrl+D'using 3)SelectIDofMLCDwhichyouwanttocontrol. keyboard. 4)TurnoffMLCD. When you use USB-to-RS-232C converters, you need to set Com Port again, because MSCS uses one of Com Port no. 1 to 30. ※Available Com Port on the PC is automatically recognized and displayed.
  • Page 16 MLCD Infinitely Expandable ORION PDP Network IP setting for MSCS 6)Click"SETTCP/IPInfo.". 1)ExecutetheMSCS. 2)Select"Menu->Communication->Setup"or"Ctrl+U"tostartsetup. 3)TypeinIPAddressofMLCD. 7)Click"GETTCP/IPInfo."andConfirmtheIPAddress. 4)Click"PingTest"tocheckstatusofcommunication. 5)ClosetheCommnicationsetupwindow ▶ Menu Description Serial :Settheserialcommunicationasadefault communication. Com Port :SettheportofaPCtocommunicatewithMLCD. Baud rate :Fixedat115200bps. ※ Caution: Users cannot change the Baud rate. Socket :SettheEthernetLANcommunication. Edit Box :SettheIPaddress....
  • Page 17: NewDesign/LastDesign"Setting

    MLCD Infinitely Expandable ORION PDP 5.6. Multi-screen configuration 5.5. "new design/Last design" setting Input the numbers of X and Y WhenComPortissuccessfullyconnected,pop-upwindowfor"Newdesign/Lastdesign" X is for the number of row and Y is for column. appears. X and Y can be selected within the range from 1 to 15. The maximum MLCD quantity of MSCS control is 100 sets.
  • Page 18: SelectingTheCommandTransmissionMethod

    MLCD Infinitely Expandable ORION PDP 5.8. Changing the input source 5.7. Selecting the command transmission method Varietiesofscreenformationsareavailablewithscreenconfiguration. OnE LCD :TransmitProtocolCommandtooneMLCD. SelectDVI,PCorVideoattheInputSelectmenu. aLL LCD :TransmittheProtocolcommandsequentiallytoallconnectedMLCDsets. Broadcast :TransmittheProtocolcommandsimultaneouslytoallconnectedMLCDsets. If you select DVI and click Play button at the Input Select menu, the input InordertocontrolpowerofspecificMLCD,use"PowerOn/Off"buttonafterselectingthe...
  • Page 19 MLCD Infinitely Expandable ORION PDP Screen formation Screen Formation with one step. TomakevariousInput-screenformation,selectaninputsourceandclickthescreenyou Youcanmakevariousmulti-screenformationswithsimplemovement. wantintheScreenconfigurationwiththeleftbuttonofthemouse. Select an input source at Source Select menu. Select PC at the Input Select menu. e.g.) In case you want to select PC e.g.) in case PC is selected...
  • Page 20: SlideControl

    MLCD Infinitely Expandable ORION PDP 5.9. Slide Control MLCDconfigurationthatuserscanchooseisdisplayedrepeatedly. TouseSlideControl,gotoMSCSMenu→Control→SlideControlorpress"Ctrl+S"using Save various screen configurations in the same way. Keyboard. Make a desirable configuration in "Screen Configurations" Click "Slide Start" to display saved screen configurations. Saved screen configurations are displaying for preset time.
  • Page 21: PictureControl

    MLCD Infinitely Expandable ORION PDP 5.10. Picture Control RegistervaluesrelatedtodisplayofMLCDcanbechanged. Click "Stop" button to end "Slide Control" TousePictureControl,gotoMSCSMenu→Control→PictureControlorpress"Ctrl+P" usingKeyboard.  I nordertocontroldisplayvalues,inputvaluesdirectlyin"EditBox"andpressEnterkey. Orclick-/+buttonusingmouse.  C lick"Exit"buttonorpress"Ctrl+X"usingkeyboardtoclose"PictureControl"window. Color Temp :Changethecolortemperatureofthescreen Save or Load the slide configuration -Normal:Initialsetting.Properfornormalvideoimageview. Click "SAVE" button to save user added Slide configuration as "*.ssd" file.
  • Page 22: OrionPdpHomePageLogOnAndVersionInformation

    MLCD Infinitely Expandable ORION PDP Control Method of optional accessory 5.11. Orion PDP Home Page log on and Version information 6.1. new MFC new MFC Connection InordertomovetoOrionPDP'swebsite,goto"Help"ofmenubar→"OrionDisplay HomePage". Connectpower. ConnectfemaleD-subtotheComportinacomputer. ConnectmaleD-subtotheRS-232CportinMLCD. InstalltheMFCconnectedwithRS-232CcableandapoweradapteratthelocationofgoodRemote controllerreception. SetthenumberoftheconnectedMLCDunitsinadvance.ThenumbercanbesetonlybytheRemote OrionPDPHomePageLogon controller. Goto"Help"ofmenubar→"About"tocheckMSCS. MLCD"NxM"Configuration New MFC Front...
  • Page 23 MLCD Infinitely Expandable ORION PDP MLCD Set Configuration (e.g. X:5 sets x Y:6 sets) Vertical configuration PressSETbutton. BROADCAST Horizontal configuration PressSETbutton. DVI 1 BROADCAST DVI 2 PressUpandDownbuttonssequentiallytoentertheverticalconfigurationmode. DVI 1 DVI 2 PressLeftandRightbuttonssequentiallytoenterthehorizontalconfiguration INFO INFO mode. DVI CONVERTER INPUT HDMI INFO...
  • Page 24: DviConverter

    MLCD Infinitely Expandable ORION PDP 6.2. DVi Converter TouseDVIConverter,gotoMSCSMenu→Device→DVIConverterorpress"Ctrl+V"using Keyboard. SettheIDofDVIConverter.TheIDcanbeselectedfrom1to9. CMnD SelectthechannelofDVIconvertertocontrol. OneofDVIChannel1(DVIC1),DVIChannel2(DVIC2),andALLDVIChannelcanbe selected. input Mode SelecttheinputmodeofDVIConverter. OneofDVI,HDMI,HDSDI,PC,DTV,S-VIDEO,andVIDEOcanbeselected. :Selectonemodefrom7InputModesandexecute. DVIConverterDialog - 44 - - 45 -...
  • Page 25 MLCD Infinitely Expandable ORION PDP Key Lock Mode Output resolution LockthefrontkeyofDVIConverternottoturnOnorOff. SettheoutputresolutionofDVIConverter. Resolution frequency 640 x 480 60Hz / 85Hz 800 x 600 50Hz / 60Hz / 85Hz 853 x 480 50Hz / 60Hz Status 1024 x 768 60Hz / 85Hz...
  • Page 26 MLCD Infinitely Expandable ORION PDP Pattern Picture Control SelecttheTestPattern(Red,Blue,8-Color,16-Gray,Green,White,White(10%),Screen) ControltheBrightness,Contrast,Sharpness,Color,andTintoftheDVIConverter. :SetorchangethePattern. Brightness :Therangeof"Brightness"youcanadjustis0to100. Contrast :Therangeof"Contrast"youcanadjustis0to100. Sharpness :Therangeof"Sharpness"youcanadjustis0to28. Color :Therangeof"Color"youcanadjustis0to100. Tint :Therangeof"Tint"youcanadjustis0to90. Firmware Default :Initializetheadjustedvaluestothedefaultvalues. Lock/Freerun Lock : D efaultsetting.ItisusedwhenMLCDisconfiguredasthedefaultdisplay. Iftheverticalfrequencyofinputsignalandoutsignalisidentical,outputisgenerated accordingtoverticalsynchronization. Freerun : T hisfunctionisusedwhenthedefaultdisplayisnotMLCDandscreenimageisnot displayed.Itgeneratesitsownoutputverticalfrequencyregardlessofinputsignal. Ifscreenimageisdisplayed,useLockmode. Lock/FreeRuncanbeconfiguredbythekeypadofDVIconverterbesidesMSCS. WhileMenuOSDisnotdisplayed,FreeRunmodecanbeselectedbypressingUPkeyandLock modebyDOWNkey.
  • Page 27 MLCD Infinitely Expandable ORION PDP Tracking PiP( Picture in Picture ) ControltheScreensize,sharpness,andpositionofDVIConverterwithPCinputmode. AvarietyofimagescanbedisplayedwiththePIPfunctionofDVIconverter.Toactivate PIP,click"PIP"intheMode.Thepositionofsub-picturecanbecontrolledbyclicking-/+ Incase alignmentdoesn'tworkthrough"TrackingAuto"command,userscantunefinely buttonsincreaseordecreasethenumberordirectlytypeinthenumbersatEditbox. through"ManualTracking". Variousinputsourcescanbeused.Tosetthesub-input,clickthesub-inputcombobox "ManualTracking"windowenablesuserstosetFrequency,Phase,LineStartandPixelStart. andselectsub-input. Detailadjustmentstepsareasfollows. Mainscreenandsub-screencanbeswappedwiththePIPSwapfunction.Press"Set" buttonattherightsideof"PIPSwap."Ifyouwanttoreturntopreviousscreen,press 1)Tune"Phase"untiltheverticallinesareclearlyadjusted.. "Normal"buttonattherightsideof"PIPSwap." 2)Tune"LineStart"toadjustverticalalignment."PixelStart"forhorizontalalignment. Mode : N ormalmode-NormalscreenwithoutPIP(PIPOff) 3) A djust"Frequency"ifalignmentisstillwrong. PIPmode-Sub-screenisdisplayedatthelowerrightcornerofthescreen.(PIPOn) Ifyouadjust"Frequency",repeatstep1)and2)tofitalignment. Position : H orizontal-AdjustthehorizontallocationofPIP.Adjustablerange0~100 Adjustablerangeisasfollows Vertical-AdjusttheverticallocationofPIP.Adjustablerange0~100...
  • Page 28: Mscs Protocol

    MLCD Infinitely Expandable ORION PDP MSCS Protocol Introduction Master(0x01):Thisisthescalercode. ETX(0x03):Theendofthecode.(Fixedvalue) ThischaptercontainsthecommunicationprotocolbetweenLCDanditscontroldevicessuchascomputerforbetter useoftheproduct.However,itdoesnotincludedetailedtechnicalmatters.Itratherfocusesonthebrieffunctional 2.2. receive From LCD explanationandcommunicationprotocol. Length Data Check Sum 1 byte 1 byte 1 byte Variable 1 byte 1 byte Controller Tx/Rx Line ID:1 ID:2 ID:N-1 ID:N (Computer)
  • Page 29 MLCD Infinitely Expandable ORION PDP 3.2. Power Off *MakeallLCDdothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand) Broadcastcommand:e.g.)Incaseof5x5MLCDformation Command for Power Off : Stand-by status ⓐ ⓑ ⓒ ⓓ ⓔ It is available only during Power On (Operative) status. Send to MLCD Normalcommand Data Length Master Value 0x02...
  • Page 30 MLCD Infinitely Expandable ORION PDP 3.5. input-Mode Change 3.7. auto-Power Mode Command for changing input mode without screen scaling Configuration for automatic power on by AC power connection. It is available only on Power On (Operative) status. It is available only on Power On (Operative) status.
  • Page 31 MLCD Infinitely Expandable ORION PDP 3.9. Over-Temperature Shut-down Control 3.11. Fan Mode Commands for automatic power off making MLCD set stand-by and OSD warning method, if IP board Command for FAN control temperature is 95℃ or higher. It is available only on Power On (Operative) status.
  • Page 32 MLCD Infinitely Expandable ORION PDP *IDrange(Program):0x01(1)~0xFF(255) *Status(32byte) *CheckSum:Execute"Not"operationafteraddingallthevaluesin"STX~Data"area. Explanation Data Length *ElapsedTime PWR Status 1 byte 0:PowerOff(Stand-by),1:PowerOn(Working) -Hundredthousands,tenthousands,thousands,hundreds,tens,ones:0(0x00)~9(0x09)rangevalue. Input Source 1 byte 0x0C:PC,0x0E:DVI,0x0D:DTV,0x07:DVD,0x05:S-Video,0x02:Video Resolution 1 byte Thevalueof"DisplayedResolutionatthetimeofdetection" Not Used 3.13. iP Serial number Global Offset 1 byte 0:GlobalOffsetOff,1:GlobalOffsetOn Color Temp.
  • Page 33 MLCD Infinitely Expandable ORION PDP 3.15. graphic User Mode Control Receive from MLCD Data Length Check Sum Command for controlling Brightness, Contrast, Sharpness Master CMD: 0x8A (Brightness), 0x8B (Contrast), 0x8C (Sharpness) Value 0x02 Variable 0x02 Variable 0X01 Variable 0x03 It is available only on Power On (Operative) status.
  • Page 34 MLCD Infinitely Expandable ORION PDP Receive from MLCD Data Length Explanation Data Video Color 1byte Range : 0(0x00) ~ 255(0xFF) Length Check Sum Master Dimming 1byte Range : 0(0x00) ~ 100(0x64) Value 0x02 0x81 0x02 Variable 0x01 Variable 0x03 Gamma...
  • Page 35 MLCD Infinitely Expandable ORION PDP Receive From MLCD Data 3.24. get Temperature Status Length Check Sum Master Value 0x02 0xDC 0x02 Variable 0x01 Variable 0x03 Command for acquiring temperature information. It is usable only at Power on status. *CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area. Send to MLCD 3.22.
  • Page 36: ※Attachment : Ascii To Hex Conversion Table

    MLCD Infinitely Expandable ORION PDP Before calling for service ※attachment : aSCii to HEX Conversion Table Beforecallingforanyrepair,checkthefollowingandthenrefertoanearA/Scenter. ▶"Tick" sound from the main body.  I fthereisnoproblemwiththescreenorsound,the"tick"soundislikelytoresultfrom thecabinetlightlyshrinkingwiththechangeofroomtemperature.Thesounddoes notaffectproduct’sperformance. ▶no image at upper and lower part of the screen. Asforascreenwhichisover16:9inwidth(suchascinema-sizedone),noimage maybedisplayedatupperandbottompartofthescreen.
  • Page 37: Applicable Signals

    MLCD Infinitely Expandable ORION PDP Applicable signals Specification Model Name OLM-4610 OLM-4650 Power Supply AC100V~240V(50/60Hz) Horizontal (Pixels) Vertical (Lines) Pixel V-Freq H-Freq Pol. Standard Resolution Clock Addr. Sync. Back Addr. Sync. Back 200W 285W Power (Hz) (KHz) (H/V) Type Total...
  • Page 38: Option Specification

    MLCD Infinitely Expandable ORION PDP Option Specification 11.1. DVi Converter 11.2. new MFC Product Name Specification Product Name Specification Powersupply 100~250VAC,50/60Hz Name MLCDREMOTECONTROL Powerconsumption 40W(MAX) Power 1.5VBattery(AAA)2EA DVI Converter Size 405mm(W)X250mm(D)X60mm(H) Remote Controller Size 55(W)x190(L)x25(H)mm (ODC-10000) EnvironmentalCondition 0℃~40℃,20~80%RH EnvironmentalCondition -10℃~40℃...

Table of Contents