DVI Converter
ODC-10000
3.18.
Get Picture Control Data
-
The command for check the current picture control data (Brightness, Contrast, Sharpness, Color, Tint) of DVI
Converter.
-
It is available only during Power on status.
-
Send to MPDP
STX
CMD
Length
Value
0x02
0x88
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0x88
0x34
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Values (39 byte)
Data
No.
1
User Mode – Brightness
2
User Mode – Contrast
3
User Mode – Sharpness
4
User Mode – Color
5
User Mode – Tint
6~39
Not Used
-
"Get Picture Control Data" Communication Sequence
* Wait for the response for 800msec after sending commands. In case of response failure, it is recommended to
send the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Get Picture Control Data Command transmission
(to Ch2)
Get Picture Control Data Command transmission
(to Ch1)
58
| ORION PDP CO., LTD.
Data
ETX
ID
Ch1/Ch2
Variable
Variable
0x03
Data
Check
ETX
Sum
ID
Ch1/Ch2
Values
Variable
Variable
...
Variable
0x03
Length
Explanation
1 byte
Range: 0(0x00) ~ 100(0x64)
1 byte
Range: 0(0x00) ~ 100(0x64)
1 byte
Range: 0(0x00) ~ 28(0x1C)
1 byte
Range: 0(0x00) ~ 100(0x64)
1 byte
Range: 0(0x00) ~ 90(0x5A)
34 byte
Get Picture Control Data Response transmission
(from Ch2)
Get Picture Control Data Response transmission
(from Ch1)
3.19.
Frame Lock Mode Control
-
It is the command to configure Frame Lock Mode.
-
It is available only at Power on and PIP Off mode status.
-
CMD: 0x6B (Free Run Mode), 0x6C (Frame Lock Mode)
-
Send to MPDP
STX
CMD
Length
Value
0x02
Variable
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
Variable
0x02
* ID range (Program): 0x65(101) ~ 0x6D(109)
* Ch1/Ch2: Channel1 (0x01), Channel2 (0x00)
* Check Sum: Add all the values of "STX ~ Data" and execute "Not" operation.
-
"Frame Lock Mode" Communication Sequence
* Wait 40msec for response. When it is failed, it is recommended to transmit the command again.
* It is recommended not to give the other command or change the resolution during transmission.
* ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1)
Frame Lock Mode Command transmission (to Ch2)
Frame Lock Mode Command transmission (to Ch1)
Infinitely Expandable
Data
ETX
ID
Ch1/Ch2
Variable
Variable
0x03
Data
Check Sum
ETX
ID
Ch1/Ch2
Variable
Variable
Variable
0x03
Frame Lock Mode Response transmission (from Ch2)
Frame Lock Mode Response transmission (from Ch1)