Chapter 19 RMON-Lite
Table 60 RMON Alarm : Create New Alarm (continued)
LABEL
Sample Type
Startup Alarm
Rising
Threshold
Falling
Threshold
Rising Event
Falling Event
Owner
Apply
Alarm Overview Click this to go back to the RMON Alarm : Overview screen.

19.6 RMON Event : Overview

Use the RMON Event : Overview screen to view and delete event entries configured on the
switch. Select [9] Event from the RMON MIB Table: drop down listbox in the RMON-Lite
screen to view the screen as shown.

Figure 80 RMON Event : Overview.

The following table describes the labels in this screen.

Table 61 RMON Event : Overview

LABEL
RMON MIB
Table:
Refresh
Create new
Event
Index
Description
Type
Community
Last Time Sent
128
DESCRIPTION
Select the method of obtaining the sample value. Choices are Absolute and Value.
Select the startup alarm type (Rising Threshold, Falling Threshold, Rising Or
Falling Threshold).
Specify a rising threshold (between 0 and 2147483647). When a value is greater or
equal to this threshold, the probe triggers an alarm.
Specify the falling threshold (between 0 and 2147483647). When a value is smaller
or equal to this threshold, the probe triggers an alarm.
Select an index number of a rising event.
Select an index number of a falling event.
Enter a descriptive name of the application that creates this entry. You can use 1-64
printable ASCII characters. Spaces are not allowed.
Click this to save the settings to the switch.
DESCRIPTION
Use this drop down list box to select the MIB table you want to view. Click Apply to
refresh the screen to the selected MIB table view.
Click this to update all the fields in the RMON Event : Overview screen.
Click this to configure new events on the switch.
This field displays an event index number. Click this number to edit the event entry.
This field displays a description of the event.
This field displays the event type (1:None, 2:Log, 3:SNMP-Trap, 4:Log-and-Trap).
This field displays the community or SNMP trap.
This field indicates the value of system up time on the switch when this event was
last generated. It appears in the following format "XXD: XXH: XXM: XXS", where
"XX" stands for a number and "D" stands for days, "H" for hours, "M" for minutes and
"S" for seconds.