Rmon Alarm: Overview; Figure 78 Rmon Alarm: Overview; Table 59 Rmon Alarm: Overview - ZyXEL Communications ES-1528 User Manual

Zyxel es-1528 ethernet switch user's guide
Hide thumbs Also See for ES-1528:
Table of Contents

Advertisement

Chapter 19 RMON-Lite
Table 58 RMON History Statistics: Control (continued)
LABEL
Jabbers
Collisions
Utilization (%)
History
Statistics
Overview

19.5 RMON Alarm: Overview

Use the RMON Alarm: Overview screen to view configured alarms that occur when the
sampled data exceeds the specified threshold. To open this screen select [3] Alarm in the
RMON MIB Table: drop down list box in the RMON-Lite screen.

Figure 78 RMON Alarm: Overview.

The following table describes the labels in this screen.

Table 59 RMON Alarm: Overview

LABEL
RMON MIB
Table:
Refresh
Create new
Alarm
Index
Interval (sec)
Variable
Sample Type
Value
Startup Alarm
126
DESCRIPTION
This field displays the number of frames dropped in this polling sample because they
were longer than 1518 octets and contained an invalid FCS, including alignment
errors.
This field displays the total number of collisions that occurred in this polling sample.
This field displays the utilization as a percentage of maximum utilization allowed on
the port in this polling sample.
Click this to go back to the RMON History Statistics: Overview screen.
DESCRIPTION
Use this drop down list box to select the MIB table you want to view. Click Apply to
refresh the screen to the selected MIB table view.
Click this to update all the fields in the RMON Alarm: Overview screen.
Click this to view the RMON Alarm: Create New Alarm screen where you can
configure the parameters for an alarm.
This field displays the alarm configuration index number. Click this number to edit the
alarm entry.
This field displays the time interval (in seconds) between data samplings.
This field displays the name of the MIB field whose data is to be sampled.
This field displays the method of obtaining the sample value (absoluteValue or
deltaValue).
This field displays the value of the statistic during the last sampling period. This value
is for comparing against the RisingThreshold and FallingThreshold values.
This field displays the alarm type (1:rising, 2:falling, or 3:risingOrFallingAlarm)
that can be sent when this alarm is first activated.
ES-1528 User's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es-1528 - v1.12

Table of Contents