Page 2
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden, Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen. particular use. In no event will Extron Electronics be liable for direct, indirect, or sollten Sie alle Sicherheits-und Bedienungsanleitungen genau Schlitze und Öffnungen •...
Page 3
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
Transmitted signal cabling ..........2-25 Termination of TP cable ..........2-26 Cable testing ..............2-26 Equalizing pair skew ............2-27 Power connector ..............2-28 Unique TP T 468 front panel features ........ 2-29 Extron TP Transmitters • Table of Contents...
Accessories ................A-7 Cables and Adapters ............A-7 Optional Adapter Plates ........... A-8 TP T 468 Template ............... A-12 Chapter One Introduction About the TP Transmitters Features All trademarks mentioned in this manual are the properties of their respective owners.
Receivers Family User’s Manual, which accompanies the receivers. A/V UTP cable or standard Category (CAT) 5 unshielded The TP T 468 is mountable in a 4-gang mud ring or electrical twisted pair (UTP), shielded twisted pair (STP), or foil shielded box installed in a wall or inset in furniture.
Extron’s MBU 125 Under Desk Mounting Kit (part #70-077-01) or MBD 129 Through Desk Mounting Kit (part #70-077-02). TP T 468 transmitter Video input — Accepts computer analog video on a 15-pin HD female connector. With an adapter cable, the transmitter can accept a Macintosh, 13W3 , RGBHV, RGBS, RGsB, component video, S-video, or composite video input.
Introduction, cont’d TP Transmitters Chapter Two Installation and Operation Installation Front Panel Control and Indicators Troubleshooting Extron TP Transmitters • Introduction...
• The TP T 15HD A, TP T 15HD AV, TP T 468, and Disconnect power from all of the equipment, including the TP T BNC may not require a local power supply for video source(s) (such as computers or DVD players), the cable lengths of 300' (91 m) or less.
TP T 15HD A TP T BNC DA4 Remove 5 BNC hex nuts. Remove 6 The TP T 468 can be configured to transmit component video, screws. S-video, or composite video. To configure the TP T 468 Lift cover Component, straight up.
Installation and Operation, cont’d Remove the two screws on each side and the screw on top Tabletop use of the cover (figure 2-2). Four self-adhesive rubber feet are included with the unit. For tabletop use, affix one foot at each corner of the bottom of the Remove (5) TP T 15HD AV Wire Pair...
Installation and Operation, cont’d Attach the rack shelf to the rack using the supplied bolts. To mount the transmitter under a desk, podium, or table top, If rubber feet were previously attached to the bottom of 1U Universal Rack Shelf the unit, remove them.
TP T 468 may not require a local power supply for cable Slide the unit up and down or back and forth in the lengths of 300’ (91.4 m) or less. If problems are mounting brackets until the front panel of the unit is at the encountered, use the local power supply.
The following Underwriters Laboratories (UL) requirements Allow enough depth for both the wall box and the cables. You pertain to the installation of the TP T 468 into a wall or furniture may need to install the cables into the wall, furniture, or (figure 2-6).
Page 15
M IN IN P Detail B Extron N IT N IT DI O TP T 468 Backing Clip can be in either orientation. See Detail A or Detail B. Foil Braided Figure 2-8 — Attaching a mud ring to a wall...
Remove power from the interface by disconnecting the Mounting the AAP devices power supply. The TP T 468 faceplates accept up to four optional single height Place the interface through the opening in the wall or Extron Architectural Adapter Plates (AAPs). The adapter plates furniture and into the wall box.
The TP T 15HD A, TP T 15HD AV, and TP T 468 may require Installing the Euro Channel transmitter grounding if all of the following conditions are true: Once the EC transmitter has been cabled and tested, the •...
Figure 2-15 — Installation features, TP T 15HD AV The TP T 15HD A (figure 2-14), the TP T 15HD AV (figure 2-15), and the TP T 468 (figure 2-16) all accept and transmit computer video and PC audio. These transmitters can...
Page 19
(TP T 15HD A and TP T 15HD AV) or a DIP switch (TP T 468) be DDSP switch — This switch turns on Digital Display Sync reconfigured.
The TP T 15HD AV (figure 2-15) accepts and transmits H/HV composite video and stereo audio. RGB/video switch (TP T 468 only) — Configures the For S-video, use the R (C-chroma) and G (Y-luma) BNCs. transmitter for RGB or component/S-video/composite video.
Installation and Operation, cont’d Termination of TP cable The Microtest OMNI SCANNER 2 performs comprehensive certification testing to the CAT 6 standards. Other Figure 2-19 details the recommended termination of TP cables in manufacturers also make testing equipment. The tests include accordance with the TIA/EIA T 568A wiring standards.
Installation and Operation, cont’d For computer video from a laptop or for ungrounded AC Min/Max LED (TP T 468 only) — This front panel LED blinks distribution systems, the transmitter may need to be red momentarily whenever the minimum or maximum limits of grounded.
Installation and Operation, cont’d TP Transmitters Appendix Specifications, Accessories, and Part Numbers Specifications Included Parts Accessories Cables/Adapters 2-32 Extron TP Transmitters • Installation and Operation...
Page 25
Audio output — Refer to the TP Receivers Family User’s from a single source Connectors Manual. TP T 15HD A, TP T 468 ... (1) 15-pin HD female (Mac and Sun/SGI to VGA adapters are available) General TP T 15HD AV ....(1) 15-pin HD female (Mac and Sun/SGI...
Page 26
#70-077-02 (MBD 129) TP T 468 ......No, but wall or furniture mountable in a wall box TP T 468 EC ...... No, but wall or furniture mountable in a Euro Channel raceway Enclosure type ......Metal Enclosure dimensions...
Optional Adapter Plates A variety of optional adapter plates for pass-through connections can be ordered for the TP T 468, which can have up to four adapter plates installed. The following configurations of adapters can be installed in a TP T 468: •...
Page 29
Specifications, Accessories, and Part Numbers, cont’d A-10 Extron TP Transmitters • Specifications, Accessories, and Part Numbers Extron TP Transmitters • Specifications, Accessories, and Part Numbers A-11...
The dashed line on the template indicates the cut-out area for installing a wall box. If you plan to install the TP T 468 without a wall box, use the smaller cut-out area indicated by the dotted lines.
Page 31
Specifications, Accessories, and Part Numbers, cont’d A-14 Extron TP Transmitters • Specifications, Accessories, and Part Numbers...
Need help?
Do you have a question about the TP T 468 and is the answer not in the manual?
Questions and answers