Gasket Replacement; Inspect The Vent System Annually; Check The Gas Flame Regularly; Glass Replacement - Vermont Castings Radiance RADVTSCCB Installation And Operating Instructions Manual

Radvt series direct vent gas heater
Hide thumbs Also See for Radiance RADVTSCCB:
Table of Contents

Advertisement

CLEANING AND MAINTENANCE

GLASS REPLACEMENT

Replace glass only with HHT approved parts. Refer to
Replacement Parts section for correct glass. Refer to
Figures 87 and 88 and previous instructions for removal
of the damaged glass frame.
Fig. 87 Remove the stove front.
ST139
Radiance
remove front
4/20/01 djt
Fig. 88 Release the latches to remove the glass frame.

GASKET REPLACEMENT

The Radiance Gas Heater uses a 'tadpole' type gasket to
seal between the glass panel and the frame. In time, this
gasket can become brittle and compressed and should be
replaced. New gasket is available from your dealer.
Shut off the gas supply and allow the stove to cool. Wear
safety goggles and a dust mask.
1. Remove the Front, Glass Frame and Glass Panel.
(Figs. 87 & 88) Remove the old gasket. Use a ra-
zor blade to separate the glass and gasket from the
frame, and to clean the glass of any remaining ce-
ment or bits of gasket. Use a cold chisel if necessary.
2. Determine the correct length of gasket by laying it
out around the edge of the glass. Allow an extra 1 -
2" (25-50mm). Mark the spot to be cut. Use a utility
knife.
5252
3. Starting on a long edge, remove about 6" of the pro-
4. Apply a thin bead of high temperature silicone rubber
5. Replace the glass frame and front panel as previously
ST139a
Fig. 89 Wrap the gasket material around the outside edge of the
glass.

INSPECT THE VENT SYSTEM ANNUALLY

Have the vent system inspected annually by a qualified
technician. Shut off the main gas supply before inspecting
the system. Both the inner exhaust pipe and the outer
combustion supply pipe must be checked to confirm that
they are unblocked and in good condition.

CHECK THE GAS FLAME REGULARLY

To ensure that the stove is operating properly, check the
ST141
flames periodically to confirm they match Figure 90. The
flames will be blue during the first 15-20 minutes of oper-
ation, and will gradually turn to yellow after that.
Do not use your stove if the flame pattern differs from that
S T141
pull glass latch
10/ 99
shown here. Contact your Vermont Castings dealer or a
qualified technician for help.
Fig. 90 Proper flame appearance
Radiance
®
tective paper strip and apply the flat adhesive face
of the gasket around the outside-facing edge of the
panel. Continue around the panel, applying about 6"
at a time and being careful to not stretch the material.
Do not overlap the gasket ends. (Figure 89)
sealant along the inside corner of the glass frame, all
around the perimeter. Place the flat gasketed side of
the glass panel back into the steel frame. Pinch the
rounded inside-facing gasket material to bulk it up.
described.
ST179
glass gasket detail
11/99
LG490
all logs
6/07
Direct Vent Gas Heater
ST179
20306759

Hide quick links:

Advertisement

Table of Contents
loading