6000 & 7000 Series DISHWASHERS
CAUTION. Switch off electrical power supply
and turn water supply off at main or isolating
valve.
The Siphon Break is positioned on the right hand side of the
stainless steel tub and provides a water fill into the stainless
steel tub via the circular vented Siphon Break Nut. The
Siphon Break Nut is threaded into the body of the Siphon
Break and fixes the Siphon Break on the exterior surface of
the stainless steel tub.
A rubber circular gasket, fitted to an annular recess in the
body of the Siphon Break, provides a positive sealing
medium between the stainless tub and the Siphon Break. The
Siphon Break has three spigots located on the lower section
of the Siphon Break body. The Water Inlet Solenoid Valve is
connected to the rear spigot
To remove the Siphon Break from the stainless steel tub
proceed as follows:
5.2.19.1 Compress the hose clamp fitted to the spigot of the
Siphon Break with hose clamp pliers as shown below and
slide clamp downward.
5.2.19.2 Grasp the hose and turn and remove from the
Siphon Break spigot.
5.2.19.3 Open the dishwasher door to gain access to the
Siphon Break Nut located on the internal right hand side
surface of the stainless steel tub as shown below. Insert a pair
of pointed nose pliers into the open vents of the Siphon Break
Nut and unscrew the Siphon Break Nut in an counter
clockwise direction approximately one and one half turns and
lift clear from the Siphon Break.
Remove Siphon Break Nut with pointed nose pliers.
5.2.19.4 Lift the Siphon Break clear from the dishwasher by
tilting the rear of the Siphon Break upwards.
5.2.19.5 Reassemble the dishwasher in reverse order.
5.2.19.6 Operate and test dishwasher before leaving.