6000 & 7000 Series DISHWASHERS
5.2.6.10
Fold the sides of the drip sheets inward and
fold the long wrap at the top of the Carrier Panel to the
bottom of the Power Control Board.
5.2.6.11 Apply adhesive tape to retain the drip sheet se-
curely.
5.2.6.12 Reassemble dishwasher in reverse order.
5.2.6.13 Operate and test dishwasher before leaving.
5.2.7 Control Panel Assembly - Models 6400, 6500
The installation of the Control Panel Assembly to the Stain-
less Steel Door Liner is covered in Sections 5.2.2-5.2.4. Prior
to removing the Control Panel from the dishwasher, remove
the Door Panel as damage to the PCB can result.
5.2.7.1 Steel Control Panel: The Steel Control Panel houses
Carrier Panel (see section 5.2.6.4) to which are attached
Dress Panels and Door Handle components to form an
operator Control Panel. Component removal/reinstallation
details are as follows.
5.2.7.2 Control Panel left hand side Dress Panel: The left
hand side Dress Panel fits over the front of the Control Panel
and clips into the Carrier Panel behind. To remove, press out
the bottom clip from behind the panel, then carefully lift the
bottom up and pull away from the front. Reassemble in
reverse order.
Bottom clip
5.2.7.3 Control Panel right hand side Dress-Panel: The
right hand side Dress Panel is attached and removed in a
similar manner to section 5.2.6.2. The three lens assemblies
are retained on the rear face of the Panel.
NOTE: While removing the Panel ensure the 6 retaining clips
are not damaged. The bottom clips should be pressed out
first during removal, and clipped in last on assembly. This will
allow the small locaters molded to the top of the panel, to
enter mating recesses in the steel Control Panel window.
Reassemble in reverse order.
5.2.7.4 Carrier Panel: The Carrier Panel is removed from the
assembly by bending the two side metal retainers on the
Control Panel to a vertical position.
NOTE: There are 4 plastic "spacers" fitted to the Carrier
Panel beneath the top metal retainers.
Unscrew 3 steel screws from the front of the Panel and lift the
Carrier Panel away from the Control Panel in an outward
and upwards direction. Reassemble in reverse order.
5.2.7.5 Power Control Board: For removal/reinstallation
refer to section 5.2.5. The procedures are similar for both
6400, 6500, 6700 & 6900 models.
5.2.7.6 Door Lock Microswitch: Refer to 5.2.4.5 for re-
moval/reinstallation of the Doorlock/ Microswitch.
5.2.7.7 Door Handle/Door Handle Cover Plate: Refer to
5.2.4.5 for removal/reinstallation of the Door Handle/Door
Handle Cover Plate.