8-52 Troubleshooting
Forgotten the login name/password to use the remote management feature through Web
browser:
→ If you have forgotten the login name or password, restore the factory default
including password by changing the BMC configuration jumper switch.
IMPORTANT:
configuration that is used for NEC DianaScope to connect with the
server.
If you are using the NEC DianaScope, you need to save the
configuration data into the floppy disk before clearing password.
BMC can be configured and saved with NEC DianaScope Agent and
the system management feature of NEC EXPRESSBUILDER.
1.
Power off the server and unplug the power cord.
2.
Change the jumper switch setting on the I/O riser board as shown below. (See I/O Riser
Board in Chapter 2 for details.)
Jumper switch location for
clearing BMC configuration data
3.
Connect the power cord.
4.
Wait at least 30 seconds with the power being off, then unplug the power cord.
5.
Restore the BMC configuration jumper switch setting and power on the server for
reconfiguration.
Restoring the factory default clears BMC
Factory-set jumper switch location