On-screen message
BB +3.3Vs Alm 09
BB +3.3Vs Alm 02
IO +3.3V AUX Alm 09
IO +3.3V AUX Alm 02
IO +1.8Vs Alm 09
IO +1.8Vs Alm 02
IO +1.2Vs Alm 09
IO +1.2Vs Alm 02
IO +1.0Vs Alm 09
IO +1.0Vs Alm 02
IO +12V Alm 09
IO +12V Alm 02
IO +5V Alm 09
IO +5V Alm 02
IO +3.3V Alm 09
IO +3.3V Alm 02
IO +1.5V Alm 09
IO +1.5V Alm 02
IO +1.0V Alm 09
IO +1.0V Alm 02
Battery Alm 09
Battery Alm 02
FP Temp Alm 09
FP Temp Alm 02
BB Temp Alm 09
BB Temp Alm 02
SASBP Temp C Alm
Description
Recommended action
+3.3Vs voltage alarm (upper limit) occurred.
+3.3Vs voltage alarm (lower limit) occurred.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
+3.3V AUX voltage alarm (upper limit) occurred on I/O riser board.
+3.3V AUX voltage alarm (lower limit) occurred on I/O riser board.
+1.8Vs voltage alarm (upper limit) occurred on I/O riser board.
+1.8Vs voltage alarm (lower limit) occurred on I/O riser board.
+1.2Vs voltage alarm (upper limit) occurred on I/O riser board.
+1.2Vs voltage alarm (lower limit) occurred on I/O riser board.
+1.0Vs voltage alarm (upper limit) occurred on I/O riser board.
+1.0Vs voltage alarm (lower limit) occurred on I/O riser board.
+12V voltage alarm (upper limit) occurred on I/O riser board.
+12V voltage alarm (lower limit) occurred on I/O riser board.
+5V voltage alarm (upper limit) occurred on I/O riser board.
+5V voltage alarm (lower limit) occurred on I/O riser board.
+3.3V voltage alarm (upper limit) occurred on I/O riser board.
+3.3V voltage alarm (lower limit) occurred on I/O riser board.
+1.5V voltage alarm (upper limit) occurred on I/O riser board.
+1.5V voltage alarm (lower limit) occurred on I/O riser board.
+1.0V voltage alarm (upper limit) occurred on I/O riser board.
+1.0V voltage alarm (lower limit) occurred on I/O riser board.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the I/O riser board.
If the same error persists, contact your service representative.
A voltage alarm (upper limit) occurred on Li-Ion battery.
A voltage alarm (lower limit) occurred on Li-Ion battery.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the Li-Ion battery mounted on base board.
If the same error persists, contact your service representative.
A high temperature alarm occurred in front panel.
A low temperature alarm occurred in front panel.
A high temperature alarm occurred in base board.
A low temperature alarm occurred in base board.
Check if fans in the server work normally.
If the same error persists, contact your service representative.
A temperature alarm occurred in SAS riser board.
Troubleshooting 8-39