4-26 Configuring Your Server
Option
Parameter
Boot
[Disabled]
Monitoring
5 minutes
10 minutes
15 minutes
20 minutes
25 minutes
30 minutes
35 minutes
40 minutes
45 minutes
50 minutes
55 minutes
60 minutes
Boot
[Retry 3 Times]
Monitoring
Always Retest
Policy
Thermal
Disabled
Sensor
[Enabled]
BMC IRQ
Disabled
[IRQ 11]
Post Error
Disabled
Pause
[Enabled]
AC-LINK
Stay Off
[Last State]
Power On
Power ON
[20] - 255
Delay Time
Platform
Disabled
Event
[Enabled]
Filtering
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC-LINK."
System status before AC power off
Operating
Aborting (DC power being off also)
Forced shutdown
* Press the POWER/SLEEP switch continuously at least four seconds. This forcibly turns off the
power.
IMPORTANT:
power source supplied from UPS when the server is connected to UPS.
Description
Indicates whether the boot monitoring
function is enabled or disabled on booting.
To use this function, install NEC ESMPRO
Agent. Do not use this function if the system
is booted from OS without installation of NEC
ESMPRO Agent or CD-ROM. Set this item to
"Disabled" if ARCServe uses the Disaster
Recovery Option.
Appears when the boot monitoring feature is
enabled. This item indicates the processing
at the occurrence of timeout during boot
monitoring.
If [Retry 3 times] is selected, the system is
reset after the occurrence of timeout and OS
boot is retried up to three times.
If [Always Reset] is selected, the system is
reset after the occurrence of timeout and OS
boot is retried repeatedly.
Indicates whether the temperature sensor
monitoring function is enabled or disabled.
Indicates the IRQ of the BMC interrupt.
Indicates whether POST is aborted once at
the end of POST if an error occurs during the
execution of POST.
Indicates the AC-LINK function. Shows the
state of the power of the server.
Sets the power on delay time when "Power
On" or "Last State" is specified for AC LINK.
Enables or disables the Platform Event
Filtering feature of the baseboard
management controller (BMC).
Setting of AC-LINK
Stay Off
Off
Off
Off
Set this item to "Power on" in order to link the AC
[
Last State
Power On
On
On
Off
On
Off
On
Your Setting
]: Factory-set