When STATUS lamp is flashing in amber
On-screen message
HDD Fault
FAN1 Alarm
FAN2 Alarm
FAN3 Alarm
FAN4 Alarm
FAN5 Alarm
FAN6 Alarm
FAN7 Alarm
FAN8 Alarm
BB +1.0V Alm 07
BB +1.0V Alm 00
BB +1.5V Alm 07
BB +1.5V Alm 00
BB +3.3V Alm 07
BB +3.3V Alm 00
BB +5V Alm 07
BB +5V Alm 00
BB +12V Alm 07
BB +12V Alm 00
BB FSB_VTT Alm 07
BB FSB_VTT Alm 00
BB +1.5V ESB Alm 07
BB +1.5V ESB Alm 00
BB +3.3V AUX Alm 07
BB +3.3V AUX Alm 00
BB +3.3Vs Alm 07
BB +3.3Vs Alm 00
Description
Recommended action
An error was detected in hard disk drive.
1. Check installation status of the failed hard disk drive.
2. While hard disk drives are in RAID configuration (RAID1, RAID5,
RAID6, RAID10, or RAID50), a single failed hard disk drive does not
affect the operation of the server. However, it is recommended to
replace the failed hard disk drive and rebuild the hard disk drives as
soon as possible.
3. If the same error persists, contact your service representative.
A warning occurred in FAN #1.
A warning occurred in FAN #2.
A warning occurred in FAN #3.
A warning occurred in FAN #4.
A warning occurred in FAN #5.
A warning occurred in FAN #6.
A warning occurred in FAN #7.
A warning occurred in FAN #8.
Check installation status of the failed fan.
If the same error persists, contact your service representative.
+1.0V voltage warning (upper limit) occurred.
+1.0V voltage warning (lower limit) occurred.
+1.5V voltage warning (upper limit) occurred.
+1.5V voltage warning (lower limit) occurred.
+3.3V voltage warning (upper limit) occurred.
+3.3V voltage warning (lower limit) occurred.
+5V voltage warning (upper limit) occurred.
+5V voltage warning (lower limit) occurred.
+12V voltage warning (upper limit) occurred.
+12V voltage warning (lower limit) occurred.
FSB VTT voltage warning (upper limit) occurred.
FSB VTT voltage warning (lower limit) occurred.
+1.5V ESB voltage warning (upper limit) occurred.
+1.5V ESB voltage warning (lower limit) occurred.
+3.3V AUX voltage warning (upper limit) occurred.
+3.3V AUX voltage warning (lower limit) occurred.
+3.3Vs voltage warning (upper limit) occurred.
+3.3Vs voltage warning (lower limit) occurred.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.