Ratings Plate - Quadra-Fire REMINGTON QFP40 Operation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

APPROVED FOR CANADA AND USA TO:
ANSI Z21.88-1998/CSA 2.33-M1998 Vented Gas Fireplace Heaters and applicable sections of UL307b
Gas Burning Heating Appliances for Mobile Homes and recreational vehicles, CAN/CGA 2.17-M91
"Gas-Fired Appliances for use at High Altitudes".
FAN TYPE VENTED CIRCULATOR
Blower Electrical Rating:
115V., 1.5 Amps, 60 Hz, 150 watts
Input Rate on "HI" (BTU/Hr)
Input Rate on "LO" (BTU/Hr)
Maximum Output (BTU/Hr)
Main Burner Orifice Front (DMS)**
Main Burner Orifice Rear (DMS)**
Minimum Inlet Pressure (Inches W.C.)
Maximum Inlet Pressure (Inches W.C.)
Manifold Pressure on "HI" (Inches W.C.)
**Equipped for installation in Canada for altitudes of 0 - 4500' (1370M); and in USA for alti-
tudes of 0 - 2000' (610M). In USA for altitudes above 2000' the vent configuration, orifice, or
combination of both may need to be changed. See Owner's Manual for information on making
these changes.
1999 2000 2001 JAN FEB MAR MAY JUN JUL AUG SEP OCT NOV DEC
Location: Serial No. portion on lip below control panel. Lower portion behind access door on
baseplate to right of control panel.
Page 6
REMINGTON QFP40 Direct Vent FIREPLACE

RATINGS PLATE

SERIAL NO.
SERIAL NO.
MODEL: REMINGTON
061-S-14-5
Thermal Efficiency* 84% NG (blower on)
* With Maximum horizontal length.
LP
NG
40,000
40,000
.
32,000
27,000
34,400
34,400
#56
#47
#53
#42
11"
4.5"
14"
7.0"
10"
3.5"
MODEL: REMINGTON
1445 N. Highway
Colville, WA 99114
86% LP (blower on)
250-4721 JUNE 2001