Glass Installation; Fascia Installation - Quadra-Fire REMINGTON QFP40 Operation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

REMINGTON QFP40 Direct Vent FIREPLACE
The glass assembly has a narrow metal edge at top of the frame, and wide metal edge at
bottom of the frame. To install the glass assembly, lift and set the bottom T-bar extensions onto
the bottom alignment pins located at the edge of firebox--refer to diagram below. With the
bottom edge of glass assembly resting on the bottom alignment pins, lift up and onto the top
alignment pins. Secure the assembly to zc appliance with the spring latches, two on top and two
at bottom.
Narrow Edge (TOP)
Flanges for fas-
cia attachment,
and T-bar exten-
sions for setting
glass onto align-
ment pins.
(2 per side)
Wide Edge (BOTTOM)
WARNING: Use care in handling of glass assembly, do not strike or slam as this
could cause breakage.
All arched and rectangular fascia attach to four flanges located two to each side of the
glass frame. Insert and finger start bolts tightening with the 5/32" Allen wrench supplied with
unit.
250-4721 JUNE 2001
INSTALLING GLASS
Spring Latches.
(2 upper & 2 lower)
T-bar extension
of Flange.
INSTALLING FASCIA
Alignment pins.
(2 per side)
Insert bolts through
these holes and into
Flanges shown in
picture above. (2 per
side)