Linking Fixtures To Power In A Chain; Fixture Overview - Martin RUSH MH 1 Profile User Manual

Martin professional rush mh 1 profile moving head user manual
Hide thumbs Also See for RUSH MH 1 Profile:
Table of Contents

Advertisement

Linking fixtures to power in a chain

If you obtain a 14 AWG / 1.5 mm
throughput cables from Martin™ (see 'Accessories' on page 41), you can relay
mains power from one fixture to another by connecting fixtures to power in a
linked daisy-chain, MAINS OUT throughput socket to MAINS IN input socket,
Using 14 AWG or 1.5 mm
Maximum four (4) RUSH MH 1 fixtures in total at 100-120 V, or
Maximum eight (8) RUSH MH 1 fixtures in total at 200-240 V.
If you install a power plug on the 14 AWG / 1.5 mm
grounding type (earthed) plug with integral cable grip that is rated minimum
250 V, 16 A.

Fixture overview

1 - Display
2 - LEDs
The fixture has two LEDs on the front of the base with the following functions:
DMX
On
SOUND
Flashing
3 - Buttons
MENU
DOWN
Go down a menu branch
UP
Go up a menu branch
ENTER
Confirm the selected function
Press and hold the MENU button to exit the menu mode.
2
cables from Martin™, you can link:
DMX input present
Sound activation
Activate the menu mode functions, or
Return to the previous level of the menu
structure, or
Hold to exit the menus
RUSH MH 1 Profile User Manual
2
power input cable and 14 AWG / 1.5 mm
2
power cable, install a
2
13

Advertisement

Table of Contents
loading

Table of Contents