Linking fixtures to power in a chain

If you obtain a 14 AWG / 1.5 mm2 power input cable and 14 AWG / 1.5 mm2 power relay (thru) cables from
Martin™ (see "Accessories" on page 35), you can relay mains power from one fixture to another by
connecting fixtures to power in a linked daisy-chain, MAINS OUT throughput socket to MAINS IN input
socket. Using 14 AWG / 1.5 mm2 cables from Martin™, you can link:
• Maximum three (3) MAC Aura XB fixtures in total at 100-120 V, or
• Maximum eight (8) MAC Aura XB fixtures in total at 200-240 V.
If you install a power plug on the 14 AWG / 1.5 mm2 power input cable, install a grounding type (earthed)
plug with integral cable grip that is rated minimum 250 V, 16 A.