TB3
Use TB3 to input/output GYRO signal.
TB4
Use TB4 to input/output the following
signal.
• Alarm signal Output
• Log signal Output
• KP signal Input
• KP signal Output
How to attach cable core to the connector
Armor
TTYCY-4S
Armor
TTYCYS-1
1. Attach the opener to the connector.
2. Push the opener.
3. Insert the cable core.
Opener
4. Release the opener.
3. WIRING
Cut off the internal
shield and sheath.
Vinyl tape
8 to 9
30
50
280
Cut off the internal
shield and sheath.
Vinyl tape
30
50
200
8 to 9