5.3 Configuration by computer

All settings can be changed by means of a computer or with a VE.Net panel (except for the multi-functional relay and the VirtualSwitch
when using VE.Net).
The most common settings (including parallel and 3-phase operation) can be changed by means of DIP switches (see Section 5.4).
For changing settings with the computer, the following is required:
-
VEConfigureII software. You can download the VEConfigureII software free of charge at
-
A RJ45 UTP cable and the MK2.2b RS485-to-RS232 interface. If your computer has no RS232 connection, but does have
USB, you will also need a RS232-to-USB interface cable. Both are available from Victron Energy.
5.3.1 VE.Bus Quick Configure Setup
VE.Bus Quick Configure Setup is a software program with which one Quattro unit or systems with a maximum of three Quattro units
(parallel or three phase operation) can be configured in a simple manner. VEConfigureII forms part of this program.
You can download the software free of charge at
For connection to your computer, a RJ45 UTP cable and the MK2.2b RS485-to-RS232 interface is required.
If your computer does not have a RS232 connection but is equipped with USB, you will also need a RS232-to-USB interface cable.
Both are available from Victron Energy.
5.3.2 VE.Bus System Configurator and dongle
For configuring advanced applications and/or systems with four or more Quattro units, VE.Bus System Configurator software must
be used. You can download the software at
You can configure the system without a dongle, and use it for 15 minutes (as a demonstration facility). For permanent use, a dongle –
available at additional charge – is required.
For connection to your computer, a RJ45 UTP cable and the MK2.2b RS485-to-RS232 interface is required.
If your computer does not have a RS232 connection but is equipped with USB, you will also need a RS232-to-USB interface cable.
Both are available from Victron Energy.
5.4 Implementing settings with a VE.Net panel
To this end, a VE.Net panel and the VE.Net to VE.Bus converter is required.
With VE.Net you can set all parameters, with the exception of the multi-functional relay and the VIrtualSwitch.
www.victronenergy.com
www.victronenergy.com
. VEConfigureII forms part of this program.
www.victronenergy.com
.
.
17