Victron Energy and Discover AES Batteries
The Discover AES range of Lithium Iron Phosphate batteries is compatible with Victron products in
various systems.
These instructions are intended to be used in conjunction with the product manual(s) supplied by
Discover Battery.
These instructions are current as of 2019-07-23. More recent updates to Victron device firmware or
Discover Battery, LYNK or Edge Card device firmware may alter set up instructions.
For the latest product details, installation and operation manuals, visit the Discover Battery website
https://discoverbattery.com
https://solar.discoverbattery.com/aes-lifepo4-batteries-renewable-energy/
1. Introduction
The Discover AES LiFePO4 Battery includes a Battery Management System (BMS) within each battery
pack. The BMS interfaces with the Victron GX device and can support multiple batteries connected in
parallel.
These instructions provide information about the integration of Discover AES Lithium batteries with
Victron Energy devices in a Closed Loop configuration using the AES LYNK Communication Gateway
with installed AES LYNK Edge Card for Victron. AES batteries can be use in an Energy Storage System
(ESS) for self consumption, Grid backup and Off-grid applications. These instructions apply to an off-
grid application.
NOTE: In a Victron networked system the charging variables will be managed automatically by the
Victron Energy - https://www.victronenergy.com/live/
1/11
» Solutions » Solar » Resources or use this direct link
Victron Energy and Discover AES Batteries

Advertisement

loading
Need help?

Need help?

Do you have a question about the MultiPlus 48/3000/35 and is the answer not in the manual?

Questions and answers

Summary of Contents for Victron energy MultiPlus 48/3000/35

  • Page 1 These instructions provide information about the integration of Discover AES Lithium batteries with Victron Energy devices in a Closed Loop configuration using the AES LYNK Communication Gateway with installed AES LYNK Edge Card for Victron. AES batteries can be use in an Energy Storage System (ESS) for self consumption, Grid backup and Off-grid applications.
  • Page 2 AES battery BMS and the Venus GX / Color Control GX device. Discharging variables are managed by the set up of the Victron inverter. 2. Documentation Victron Energy Reference Documents: Quattro Inverter Charge Manual MultiPlus Inverter Charge Manual SmartSolar / BlueSolar Charge Controller Manual...
  • Page 3: System Overview

    2020-11-12 10:43 3/11 Victron Energy and Discover AES Batteries Failure to follow these instructions can damage equipment 3. Overview 3.1 System Overview The AES LYNK Communication Gateway unlocks the full potential of a Discover AES LiFePO4 Battery by enabling the internal Battery Management System (BMS) to optimize the charge and discharge configurations of the world’s best inverter chargers and solar charge controller systems in a closed...
  • Page 4 Last update: battery_compatibility:discover https://www.victronenergy.com/live/battery_compatibility:discover?rev=1597358648 2020-08-14 00:44 *92% Efficiency at 48V Model Inverter Peak* Charger 1-Phase Min 44-44-2800 MultiPlus / Quattro 24/3000/70 271 Adc 70 Adc MultiPlus / Quattro 24/5000/120 452 Adc 120 Adc 2 MultiPlus / Quattro 24/8000/200 724 Adc 200 Adc 3 *92% Efficiency at 24V 4 Configuring Victron Products...
  • Page 5 2020-11-12 10:43 5/11 Victron Energy and Discover AES Batteries General Tab 44-24-2800 42-48-6650 Overruled by remote (1) Enable Enable Enable battery monitor Enable Enable SoC when Bulk finished (2) Total battery capacity (per battery installed) installed x 110 Ah installed x 130 Ah Charge efficiency (2)| 95% |95%|...
  • Page 6 Last update: battery_compatibility:discover https://www.victronenergy.com/live/battery_compatibility:discover?rev=1597358648 2020-08-14 00:44 MPPT Charge Controller Settings 44-24-2800 42-48-6650 Battery voltage 24 V 48 V Max current per battery installed installed x (78 A < 110 installed x (92 A < 130 (Recommended < Maximum) (9) Charger enabled Enabled Enabled Battery preset...
  • Page 7 2020-11-12 10:43 7/11 Victron Energy and Discover AES Batteries Choose a clean, dry, easily accessible indoor location. All the communication ports on the LYNK are accessible from the bottom of the device when mounted on a wall or DIN rail. Clearance of at least 50 mm (2 inches) below the device is needed to allow for the bend radius of cables connected to LYNK.
  • Page 8: System Setup

    Last update: battery_compatibility:discover https://www.victronenergy.com/live/battery_compatibility:discover?rev=1597358648 2020-08-14 00:44 6. System Set Up 6.1 Synchronizing the Victron System with the AES Battery Turn the Discover AES battery to ON press and hold switch on the battery/batteries for 2-3 seconds. Turn on all Victron equipment. Through the VRM or a physical CCGX access the System Setup menu in the Remote Console.
  • Page 9 2020-11-12 10:43 9/11 Victron Energy and Discover AES Batteries * Within the “CAN-bus Profile” choose “VE CAN & CAN-bus” * “VE CAN-bus & CAN-bus BMS (250 kbit/s)” should appear on the “CAN-bus(1) menu Victron Energy - https://www.victronenergy.com/live/...
  • Page 10 Last update: battery_compatibility:discover https://www.victronenergy.com/live/battery_compatibility:discover?rev=1597358648 2020-08-14 00:44 Return to the Device List and the CCGX should display Discover AES as one of the devices along with the battery SoC, Voltage and Amps. If you have multiple batteries a single entry will show up, which represents all batteries.
  • Page 11 2020-11-12 10:43 11/11 Victron Energy and Discover AES Batteries SCS Status - Should show “Disabled (External Control) (8) Limit charge current works across the whole system. MPPTs are automatically prioritized over the mains. In case the AES BMS requests a maximum charge current that is different from the user- configurable setting, the lower of the two will be used.