Dimplex SOLCU Installation And Operating Instructions Manual page 69

Temperature difference controller 5 inputs, 2 outputs
Table of Contents

Advertisement

Maximum temperature loading circuit:
Factory
Adjustable
setting
down to
min.
100 °C
Minimum
loading cir-
cuit tempera-
ture +0 K
Minimum temperature loading circuit:
Factory
Adjustable
setting
down to
min.
0 °C
0 °C
Loading strategy storage tank 1 and storage tank 2:
Factory
Adjustable
setting
down to
min.
Temperature differential control
8 K
 K
Target temperature control
60 °C
0 °C
RPM control pump R1:
Factory
Adjustable
setting
down to
min.
50 %
30 %
EN
Adjustable
Description
up to max.
130 °C
When the temperature on the secondary side in
the heat exchanger reaches 3 K below the defined
maximum value, the solar circuit pump is switched
off and the storage tank loading pump continues
to run. When the temperature drops back down
to 10 K below the maximum value, the solar pump
switches on again. If the defined maximum value
is nevertheless reached, the storage tank loading
pump also switches off, for safety reasons. When
the temperature returns to below the maximum
temperature, the storage tank loading pump
switches on again.
Adjustable
Description
up to max.
Maximum
The storage tank loading pump is not switched on
temperature
until the temperature on the secondary side of the
loading circuit
heat exchanger has reached the defined minimum
-0 K
temperature.
Adjustable
Description
up to max.
It is possible to choose between temperature dif-
ferential loading and target temperature load-
50 K
ing. Depending on the selected loading strategy,
the controller either attempts to comply with the
95 °C
defined temperature difference between collector
and storage tank, or to reach the defined target
temperature as quickly as possible. See chapter
7.4. for information regarding settings.
Adjustable
Description
up to max.
100 %
If RPM control is activated, the power at the control-
ler's output R1 is regulated by means of full-wave
packet control, according to the measured tempera-
ture values and controller settings.
When RPM control is deactivated, full power is
present at the controller's output R1. See chapter
7.4.3 for information regarding settings.
730.138 | 08.1
69