Dimplex SOLCU Installation And Operating Instructions Manual page 39

Temperature difference controller 5 inputs, 2 outputs
Table of Contents

Advertisement

[.................]
[.................]
Display: 3.1.4
Display: 3.1.4
[Temp. controlled]
[Temp. controlled]
T
T
?
?
[...]: 30°C
[...]: 30°C
[...]: 35°C
[...]: 35°C
Display: 3.1.4.1
Display: 3.1.4.1
[on]
[on]
[off]
[off]
[................]
[................]
Display: 3.1.5
Display: 3.1.5
[Pulse controlled]
[Pulse controlled]
Input:
Input:
?
?
Circulation:  min
Circulation:  min
Wait time:
Wait time:
10 min
10 min
Display: 3.1.5.1
Display: 3.1.5.1
EN
Activating temperature control
"Functions" submenu selected, see "Selecting a function"
(see chapter 7.3.1).
Circulation activated, see "Activating a function" (see chapter 7.3.1)
Outputs selected, see "Selecting an output" (chapter 7.3.1).
: press button.
The "Temp. controlled" display appears.
SET: press button.
 
Temperature control is activated.
: press button.
The display for setting the temperature input and the "on" and
"off" values appears.
SET: press button.
"T" flashes in the display (circulation pipe temperature input).
: choose the desired input.
SET: press button to confirm.
The "on" value flashes after confirmation of the temperature
sensor.
: set the "on" value.
SET: press button to confirm.
 
The "off" value flashes after confirmation of the "on" value.
: set the "off" value.
SET: press to confirm and close.
The settings are saved.
Activating pulse control
"Functions" submenu selected, see "Selecting a function"
(see chapter 7.3.1).
Circulation activated, see "Activating a function" (see chapter 7.3.1).
Outputs selected, see "Selecting an output" (chapter 7.3.1).
: press button.
The "Pulse controlled" display appears.
SET: press button.
 
Pulse control is activated.
: press button.
The display for setting the pulse input, circulation time, and wait
time appears.
SET: press button.
Pulse input flashes.
: choose the desired input.
SET: press button to confirm.
 
The circulation duration flashes after confirmation of the input.
: set the circulation duration.
SET: press button to confirm.
The wait time flashes after confirmation of the circulation duration.
: set the wait time.
SET: press button to confirm the wait time and close.
The settings are saved.
ESC: leave the "Circulation" submenu.