Dimplex SOLCU Installation And Operating Instructions Manual page 38

Temperature difference controller 5 inputs, 2 outputs
Table of Contents

Advertisement

NOTE
R? or T? indicates an output or input which has not yet been selected.
Only outputs which are not yet required by the respective system can be
selected. Double allocation of outputs is not possible. However, double
allocation of inputs is possible. This is also displayed in an information
window (see chapter 11).
Leaving the menu
ESC: press button.
7.3.2
Circulation function
A circulation pump can be controlled in a time-based, temperature-
based, or pulse-based manner. These types of control can also be com-
bined with each other.
Time control: time switch with 3 time windows.
Temperature control: When the temperature in the circulation return
falls below the "on" value, then the pump is switched on until the "off"
temperature is reached.
NOTE
In order to avoid measurement errors caused by the pipe's thermal con-
duction, a minimum clearance space of 1.50 m from the storage tank
should be observed when installing the circulation sensor.
Pulse control: When the circulation function is requested via a pulse
(e.g. from a flow switch), the pump runs for the set circulation duration.
Subsequently, no further requests are accepted until the set wait time
has expired.
Activating time control
"Functions" submenu selected, see "Selecting a function"
(see chapter 7.3.1).
Circulation activated, see "Activating a function" (chapter 7.3.1).
Outputs selected, see "Selecting an output" (chapter 7.3.1).
: press button.
The "Time controlled" display appears.
SET: press button.
Time control is activated.
: press button.
The display for setting the duration appears.
SET: press button.
The time flashes in the display.
: set the duration.
SET: confirm the value and go to the next value.
The settings are saved.
NOTE
The switch-on time must always be before the switch-off time. There-
fore, when the switch-on value is being adjusted, the switch-off value
will also be changed to a later time if necessary. Adjusting the switch-off
value to a time before the switch-on value is blocked.
38
EN
 
[...............]
[...............]
Display: 3.1
Display: 3.1
[Circulation]
[Circulation]
 
Display: 3.1.3
Display: 3.1.3
[Time controlled]
[Time controlled]
 
Display: 3.1.3.1
Display: 3.1.3.1