Adapting To The Different Types Of Gas - Elba EGH-B9230G Owner's Manual

Built-in glass hob
Table of Contents

Advertisement

ADAPTING TO THE DIFFERENT TYPES OF GAS

Changing the nozzles
1)
Remove the pan standee.
2) Remove the burner caps and flame caps from the
burners.
3) Use a size 7 socket wrench to unscrew and remove
the nozzles, replacing them with those corresponding
to the type of gas to be used (see the table ).
4) Reassemble the parts, reversing the operations
described above.
5) Then replace the setting data (close to the mains gas connection)with the
one for the new type of gas If the pressure of the gas used is different from
that specified(or variable),a suitable piped gas pressure regulator
complying with the standard must be installed on the supply pipeline.
Setting the minimum level
1) Light the burner as already described.
2) Turn the tap to the minimum flame position.
3) Remove the control knobs.
4) Use a thin straight screwdriver to turn the by-pass pin
located next to the tap rod (see fig. B).For LPG, turn the
by-pass pin fully clockwise.
The result should be a small, homogeneous flame
which is uniform around the entire burner ring. For the dual Triple
Flame version see fig. A. by-pass 1 central burner,
by-pass 2 both burners.
5) Finally, check that the burner does not go out when the
tap is turned quickly from the maximum to the minimum
position.
A
B
12

Advertisement

Table of Contents
loading

Table of Contents