WARNING: Carefully supervise young children when they are in the room with the heater.
WARNING: Make sure grill guard is in place before running heater.
WARNING: Keep the appliance area clear and free from combustible materials, gasoline, and other flam-
mable vapors and liquids.
1.
This appliance is for use with only the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases.
2.
Do not place Propane/LP supply tank(s) inside any structure. Place Propane/LP supply tank(s) outdoors.
3.
If you smell gas
•
Shut off gas supply.
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
•
If you cannot reach your gas supplier, call the fire department.
4.
Models MN/L 100HPH and MN/L100TPH shall not be installed in a bathroom.
5.
This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for
Combustion and Ventilation, pages 5 through 6. If heater keeps shutting off, see Troubleshooting, pages 18
through 20.
6.
Keep all air openings in front and bottom of heater clear and free of debris. This will ensure enough air for
proper combustion.
7.
If heater shuts off. Do not relight until you provide fresh, outside air. If heater keeps shutting off, have it ser-
viced.
8.
Do not run heater:
•
Where flammable liquids or vapors are used or stored.
•
Under dusty conditions.
9.
Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors
from these products may create a white powder residue within burner box or on adjacent walls or furniture.
10. Always run heater with control knob at PILOT/IGN, LOW or HIGH locked positions. Never set control knob
between locked positions. Poor combustion and higher levels of carbon monoxide may result.
11. Do not use heater if any part has been under water. Immediately call a qualified service technician to
inspect the room heater and to replace any part of the control system and any gas control which has been
under water.
12. Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and
repair heater.
13. Operating heater above elevations of 4,500 feet could cause pilot outage.