MANUAL LIGHTING PROCEDURE

1.
Remove front panel.
2.
Follow steps 1 through 5 under "Lighting Instructions" on page 14.
3.
With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4.
Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release
knob. Follow step 8 under "Lighting Instructions" on page 14.
5.
Replace front panel.
TO SELECT HEATING LEVEL
WARNING: When running heater, set control knob at PILOT IGN, LOW or HIGH locked positions (see
Figure 19). Never set control knob between locked positions. Poor combustion and higher levels of carbon
monoxide may result.
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
Slightly press in control knob and turn conterclockwise
19)
to the ON, LOW or HIGH positions (see Figure
Figure 19


control