Status Monitor

The Status Monitor is the sub LCD in the rear panel
of LX601i, LW551 and LWU501i. The Status Monitor
displays the present condition of the projector
including errors, setup information and error history.

Displaying the condition of the projector

If no buttons have been operated, the Status Monitor displays as below depending
on the condition of the projector.
NOTE
• The Status Monitor displays nothing while the projector is in standby
mode if the STANDBY MODE item of SETUP menu is set to SAVING (57).
• When INSTALLATION in the SETUP menu is set to FRONT / CEILING or REAR /
CEILING, the contents on the Status Monitor are displayed upside down (56).
 In a normal state
The Status Monitor displays the state of the projector
in three lines.
: Displays the status of the projector.
1st line
While the lamp is on, the selected port is
displayed.
Displayed status is as below;
STANDBY: The projector is in standby mode.
WARM UP: The projector is warming up.
SEARCHING: The projector is searching an input signal.
COOL DOWN: The projector is cooling down.
: Displays the status of the detected input signal while the lamp is
2nd line
on. Otherwise, displays the serial number of the projector.
Displayed status is as below;
SYNC OUT: Detected input signal is out of specified range.
NO SIGNAL: There is no input signal.
CONNECTED: The projector has connected to the network or the computer
and some image is transferred to the projector while the LAN or USB TYPE
B port is selected.
HOLD: The projector has connected to the network but no image is transferred
while the LAN port is selected.
NOT CONNECTED: The projector is not connected to the network or the
computer while the LAN or USB TYPE B port is selected.
(continued on next page)
Operating Guide
LX501/LX601i/LW401/LW551i/LWU421/LWU501i
Status Monitor <Only for LX601i, LW551i and LWU501i>
<Only for LX601i, LW551i and LWU501i>
21
Status Monitor
S T A N D B Y
# 1 2 3 4 5 6 7 8
example
020-000461-02 Rev. 1 (06-2012)
9
0 A B
2 3 ° C