Samlexpower G4-2012A Owner's Manual page 69

G4 invercharge inverter/charger pure sine wave
Table of Contents

Advertisement

SECTION 10 |
Parameter
bATTeRY CHARGeR SeCTIon (ConTInUeD)
Equalization Current
Equalization Time
Maximum Charging Efficiency
Battery Initial voltage
Over Charge Current Protection
Battery Charging voltage Temperature
Compensation (with external Battery
Temperature Sensor Model BTS-G4)
External DC Fuse Protection (Max.)
Over voltage Protection and Alarm
Parallel operation with external charger
Charging voltage range with external
charger
Maximum charging current with
external charger
General
Parameter
Safety Compliance
EMI / EMC Compliance
Operating Temperature Range
Storage Temperature
Operating Humidity
Audible Noise
Earthing
Dimensions (W x D x H) millimeters
Dimensions (W x D x H) inches
Weight (kg., Lb)
Specifications
g4-2012a
Automatic - 0.5 times the set value of Bulk Charge Current
Automatic - based on the time the battery remains in Bulk Stage
70% at charging current = 45A
9 to 16 vDC
95A (Shut down charging)
Compensation is effective over temperature range of - 20°C to + 50°C
Programmable Coefficient of Compensation: -3 to - 5 m v / °C / cell
Default: - 4 mv / °C / cell Reference: 25°C
320A
> Programmed Boost voltage
> Programmed Equalization voltage
Charger off
Green LED - OFF; Red LED - ON
1 beep @ 0.5 sec
> Programmed Boost voltage
+ 0.8v for 30 sec
> Programmed Equalization
voltage + 0.6v for 30 sec
Charger off. Transfer to
Inverter Mode
Green LED OFF; Red LED
blinks
3 beeps @ 5 sec
yes. The total charging current will follow the programmed Bulk Current setting.
13 to 16 vDC
50A
g4-2012a
Intertek-ETL listed: Conforms to ANSI / UL STD. 1741
Intertek-ETL listed: Certified to CAN / CSA STD. C22.2 No. 107.1-01
Intertek-ETL listed: Conforms to ANSI / UL STD. 458
Certified to FCC Part 15(B), Class A
Certified to ISO 7637-2 for immunity against conducted electrical transients in vehicles
0°C to +50°C / 32°F to 120°F
-15° C to +60°C / 5°F to 140°F
5% to 95%
Maximum 65 dBA from distance of 1 meter
External Earth Ground terminal for connecting the Equipment Grounding Conductor
218 x 558 x 198 mm
8.6" x 22" x 7.8"
24.1 Kg, 53.0 lb.
g4-2524a
80% at charging current = 20A
18 to 32 vDC
85A (Shut down charging)
195A
> Programmed Boost voltage
+ 1.6 v for 30 sec
> Programmed Equalization
voltage + 1.2 v for 30 sec
Charger off. Transfer to
Inverter Mode
Green LED OFF; Red LED
blinks
3 beeps @ 5 sec
26 to 32 vDC
50A
g42524a
24.6 Kg, 54.1 lb.
g4-3524a
80% at charging current = 20A
18 to 32 vDC
85A (Shut down charging)
290A
> Programmed Boost voltage
+ 1.6 v for 30 sec
> Programmed Equalization
voltage + 1.2 v for 30 sec
Charger off. Transfer to
Inverter Mode
Green LED OFF; Red LED
blinks
3 beeps @ 5 sec
26 to 32 vDC
50A
g4-3524a
26.1 Kg , 57.4 lb.
SAMLEX AMERICA INC. | 69

Advertisement

Table of Contents
loading

This manual is also suitable for:

G4-2524aG4-3524a

Table of Contents