SECTION 9 |
Shut Down Due To Fault Conditions & Reset
!
CAUTIon! Please note that "shut down" indicates that the output has been stopped.
The unit will not completely turn oFF under "shut down" condition.
The unit will shut down in certain critical fault conditions and will require manual reset. Switch OFF the unit using the ON/OFF key. Remove the cause of
defect and switch ON the unit again.
In some cases, the unit may get latched and will not switch OFF. In such cases, remove the AC & DC input connection, wait for 5 minutes, reconnect
and then switch ON.
Protections
Table 9.2 gives the details of protections provided for safe and reliable operation of the unit:
SYMPToM
Low DC input voltage protection - alarm
(Inverter Mode)
11.0 vDC ± 0.3 vDC for 12v battery
22.0 vDC ± 0.6 vDC for 24v battery
Low DC input voltage protection – shut down
Inverter Section / (Inverter Mode)
10.0vDC ± 0.3vDC for 12v battery
20.0vDC ± 0.6vDC for 24v battery
High DC output voltage of internal AC charger (In
Utility / Generator Mode)
In normal 3 Stage Charging Mode:
• Voltage > programmed Boost (Absorption)
voltage ± 0.3v (12v battery)
• Voltage > programmed Boost (Absorption)
voltage ± 0.6v (24v battery)
In 4 Stage equalization Mode
• Voltage > programmed Equalization Voltage
± 0.3v (12v battery)
• Voltage > programmed Equalization Voltage
± 0.6v (24v battery)
High DC output voltage of internal AC charger
for 30 seconds protection (In Utility / Generator
Mode)
In normal 3 Stage Charging Mode:
• Voltage > programmed Boost (Absorption)
voltage + 0.8 ± 0.3v (12v battery)
• Voltage > programmed Boost (Absorption)
voltage + 1.6 ± 0.6v (24v battery)
In 4 Stage equalization Mode
• Voltage > programmed Equalization Voltage
+ 0.6 v ± 0.3v (12v battery)
• Voltage > programmed Equalization Voltage
+ 1.2 v ± 0.6v (24v battery)
Protections, Operational
Monitoring & fault diagnosis
TAbLe 9.2: PRoTeCTIonS
"Status" LeD -
"Fault"
GReen
LeD - ReD
Blinking 1
Blinking 1
@ 2 sec
@ 0.5 sec
OFF
OFF
OFF
ON
OFF
Blinking
buzzer Alarm
3 beeps per
30 sec
OFF
1 beep @ 0.5 sec
Charger is turned OFF
3 beeps @ 5 sec
Charger is turned OFF
Unit transfers to Inverter Mode
SAMLEX AMERICA INC. | 57