Samlexpower G4-2012A Owner's Manual page 52

G4 invercharge inverter/charger pure sine wave
Table of Contents

Advertisement

SECTION 8 |
< 20 ms) and switch on again after some time because the drive circuitry
of the lamp shuts down and takes some time to reactivate to re-light the
lamp. Hence, this symptom in a CFL will falsely indicate a larger transfer
time. Computers, audio video devices and other electronics normally
have holdup time of > 20 ms and will not be affected by this short
interruption of power.
LCD Screens And LeD Display
In The "Generator Mode"
i
InFo
The main bi-directional Transformer is protected against over
temperature during battery Charging Mode by reducing the
charging current to 50% if the transformer temperature > 120°C.
Hence, during charging process, the internal charging current
being displayed on the LCD display might drop to half the value
when the temp > 120°C. once the transformer cools down, the
charging current will resume to the full value. This cycling may
repeat a number of times till the transformer temperature does
not rise > 120°C.
When in "Generator Mode", the Green Status LED will be steady.
The following 6 LCD screens of information can be accessed in the
"Generator Mode". The screens can be scrolled using the "Up" or
"Down" Keys.
Please note that the up to down order of appearance of the screens
shown below (Screen 1
Screen 2
Screen 5
Screen 6
Screen 1
using the "Up" Key. The order will be reversed (bottom to top i.e. Screen
6
Screen 5
Screen 4
Screen 2
Screen 1
Screen 6
Key is used. Please also note that the scrolling of the display screens is in
a continuous loop.
SCReen 1
Press "Up" Key to go to SCREEN 2
G
e
n
e
r
a
SCReen 2
Press "Up" Key to go to SCREEN 3
I
n
p
u
t
S
x
x
x
v
a
SCReen 3
Press "Up" Key to go to SCREEN 4
O
u
t
p
u
t
x
x
x
v
a
52 | SAMLEX AMERICA INC.
Operation
Screen 3
Screen 4
Screen 2, etc.) is valid when
Screen 3
Screen 5, etc.) if the "Down"
t
o
r
M
o
d
t
a
t
u
s
c
x
.
x
H
S
t
a
t
u
s
c
x
x
.
x
SCReen 4
Press "Up" Key to go to SCREEN 5
B
a
t
t
x
x
x
oR
B
a
t
t
I
n
p
nOte: This screen will be displayed when the frequency of the generator
is outside the range of 45 to 65 Hz. Charging is stopped during this
condition.
SCReen 5
Press "Up" Key to go to SCREEN 6
E
x
oR
E
x
nOte: This screen will be displayed when the frequency of the generator
is outside the range of 45 to 65 Hz. Charging is stopped during this
condition.
SCReen 6
C
h
a
r
oR
e
C
h
a
r
oR
C
h
a
r
H
z
oR
C
h
a
r
I
n
p
nOte: This screen will be displayed when the frequency of the generator is
H
z
outside the range of 45 to 65 Hz. Charging is stopped during this condition.
e
r
y
C
h
a
A
x
e
r
y
C
h
a
H
z
A
b
n
t
.
I
A
t
.
I
A
g
i
n
g
M o
B
u
l
K
g
i
n
g
M o
B
o
o
s
t
g
i
n
g
M o
F
l
o
a
t
g
i
n
g
M o
H
z
A
b
n
r
g
i
n
g
x
.
x
v
r
g
i
n
g
o
r
m
a
l
n
t
.
A
n
t
.
O
A
d
e
d
e
d
e
d
e
o
r
m
a
l

Advertisement

Table of Contents
loading

This manual is also suitable for:

G4-2524aG4-3524a

Table of Contents