SECTION 8 |
operation In Inverter Mode
In "Inverter Mode" the following input / output connections are made:
• As AC input power is NOT available, nothing is connected to the AC
Input terminals.
• The AC output terminals are connected to the AC distribution wiring
• The battery is connected to the Battery Input Terminals
• If a parallel external charging source (e.g. charge controller fed from
solar array or another AC charger) is required to charge the batteries,
it should be connected to the auxiliary DC input terminals
LCD Screens and LeD Display in

Inverter Mode

When in "Inverter Mode", the Green Status LED will be blinking – 1 blink
@ 2 sec. The following 5 LCD screens of information can be accessed
in the "Inverter Mode". The screens can be scrolled using the "Up" or
"Down" Keys.
Please note that the up to down order of appearance of the screens
shown below (Screen 1
Screen 2
Screen 5
Screen 6
Screen 1
using the "Up" Key. The order will be reversed (bottom to top i.e. Screen
6
Screen 5
Screen 4
Screen 2
Screen 1
Screen 6
Key is used. Please also note that the scrolling of the display screens is in a
continuous loop.
SCReen 1
Press "Up" Key
I
n
v
e
r
t
SCReen 2
Press "Up" Key
I
n
p
u
t
S
x
x
x
v
a
SCReen 3
Press "Up" Key
O
u
t
p
u
t
x
x
x
v
a
SCReen 4
Press "Up" Key
O
u
t
p
u
t
Operation
Screen 3
Screen 4
Screen 2, etc.) is valid when
Screen 3
Screen 5, etc.) if the "Down"
e
r
M
o
d
e
t
a
t
u
s
c
x
x
.
x
S
t
a
t
u
s
c
x
x
.
x
P
o
w
e
r
oR if the output is > 1 KW, the power will be displayed in KW as follows:
SCReen 5
Press "Up" Key
B
a
t
t

equalizing batteries

equalization Procedure -
Safety Instructions
WARnInG!
Please note that equalization generates
explosive gas mixture of Hydrogen and oxygen.
ensure that during equalization, the area where
the battery is installed has adequate ventilation
to extract / dissipate the explosive gas mixture.
!
H
z
CAUTIon!
Sealed AGM / Gel Cell batteries must neVeR
be equalized. These types of batteries may fail
prematurely if equalized. As a general rule, do
not equalize a battery unless there are vented
removable caps for the cells to add water to the
cells of the battery.