Optional Equipment
8
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly
leak-test all gas connections and the gas control valve. Check the pilot. Adjust if necessary.
WARNING:
When lighting or re-lighting the pilot, the glass must be removed (see page 41).
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
Fireback Installation
WARNING Turn off gas to the appliance and make sure it has fully cooled prior to conducting service.
1
Remove the glass frame and logs.
2
Remove the front and rear burners (see page 62).
3
Remove and discard the hearth plate.
© Travis Industries
Standard
Screwdriver
Hearth Plate
4050207
(for qualified installers only)
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
65