Facing Overview
Upgrade faces are available for this fireplace and may influence facing installation. Consult with your
Travis Dealer if you are using an upgrade face.
Optional non-combustible facing may be installed on the fireplace. Use the guidelines below to
determine the location (also see the following pages for detailed diagrams.
Tile Line
Any non-combustible facing under 1" thick (see "Thin Facing" on page 35).
Masonry Line
Any non-combustible over 1" thick (see "Thick Facing" on page 37).
Hearth Line
Non-combustible hearth/facing should be installed up to this location (1" above the base
of the fireplace). The fireplace may be raised to accommodate thicker hearth materials.
© Travis Industries
Installation
(for qualified installers only)
NOTE: The hearth or facing can extend no
greater than 1" above the base of the fireplace.
The fireplace may be raised to accommodate
thicker hearth materials.