Optional Equipment
Blower Installation
Make sure power to the fireplace has been turned off prior to installation (disable the service breaker).
Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace.
It is easier to install the blower prior to connecting the gas line.
1. Attach the right side blower to a
blower bracket following the
directions below.
2. Repeat step 1 for the left side
blower.
3. Attach the blowers (use the
#8 x 3/4" silver screws) and
snap disc (see the
directions below).
NOTE: Make sure the
grommets (and bushings)
stay in place while
installing. The rubber
grommets insulate the
fireplace from any blower
vibration (reducing noise).
© Travis Industries
(part # 99000156)
Make sure these two
grommets are in place
(they insulate the fireplace
from blower vibration)
4050207
(for qualified installers only)
Install the brackets to the blower with
two #8 x 3/8" (shorter, silver) screws.
67
Make sure these two grommets
and bushings are in place.
Side View
Bushing
Blower
Bracket
Grommet
100-01168