Management Agent

3.3.4.4 Server Blade Memory

This option provides information on the server blade memory. The information is displayed in two tables:
Table
Server Blade Memory Information
Table
Server Blade Memory Modules Table

3.3.4.5 Server Blade Voltage Table

This option provides information on the server voltage. The following parameters are displayed:
Parameter
Server Voltage Designation
Server Voltage Status
Server Voltage Minimum Value Displays the minimum voltage value for the server blade.
Server Voltage Maximum Value Displays the maximum voltage value for the server blade.
Server Voltage Current Value
Server Voltage Nominal Value

3.3.4.6 Server Blade Temperature

This option provides information on the server temperature. Some of the parameters displayed can also be set by
the user:
Parameter
Server Temperature Sensor Designation
Server Temperature Sensor Status
Server Temperature Upper Warning Level
Server Temperature Upper Critical Level
Server Temperature Lower Warning Level
Server Temperature Lower Critical Level
Server Temperature Current Value
24
Description
Displays information on the total size of the memory, as well as on the
error count, the error reset record and the error count start time.
Displays the status of each memory module, together with memory type
and error information.
Description
Displays the voltage designation for the server blade.
Displays the voltage status for the server blade. The values displayed will be:
– NOT_AVAILABLE
– OK
– TOO_LOW
– TOO_HIGH
Displays the current voltage value for the server blade.
Displays the nominal voltage value for the server blade.
Description
Displays the designation of the temperature sensor for the
server blade.
Displays the status of the temperature sensor. The values
displayed will be:
– SENSOR_DISABLED
– SENSOR_FAIL
– WARNING_TEMP_WARM
– CRITICAL_TEMP_WARM
– NOT-AVAILABLE
This parameter can be set to configure the upper warning level
of the temperature sensor for the server blade.
This parameter can be set to configure the upper critical level
of the temperature sensor for the server blade.
This parameter can be set to configure the lower warning level
of the temperature sensor for the server blade.
This parameter can be set to configure the lower critical level
of the temperature sensor for the server blade.
Displays the current temperature value for the server blade.
ServerView BX900 S1 Management Blade