Server Blade - Fujitsu PRIMERGY BX900 User Manual

Blade server systems, serverview management blade s1, user interface description
Hide thumbs Also See for PRIMERGY BX900:
Table of Contents

Advertisement

Telnet Interface
The menu offers the following subordinate options to the user:
Parameter
System Control Information
System Power Supply
System Fan
System Temperature
System Chassis Table
System UPS
ID LED Control
NIC Status Detection
Turn on/off all server blades
Automatic Inventory Retrieval The function is only working for VIOM. If set to automatic, the inventory retrieval
Scheduled Power-On/Off
Time

3.3.4 Server Blade

The Server Blade option provides general information on the server blades, i. e. information on CPUs, memory
modules, voltage, temperature, CMOS configuration and watchdog timers.
The menu for this option looks like this:
Figure 7: Server Blade menu
ServerView BX900 S1 Management Blade
Description
Displays the number of system fans, power supply groups and temperature
sensors, as well as the status of all system components, excepting CPU blades
and connection blades.
Displays information on the power supply units.
Displays information on the number and status of the system fans, including
parameters like nominal speed, current speed, speed threshold and failure
reaction. A fan test is also provided, supporting the fan life time monitor.
Displays information on the system temperature, including current value,
warning level, critical level, sensor status and critical temperature reaction.
Displays information on the system chassis, including the chassis serial number
and if there has been any intrusion into the inside of the chassis.
Displays chassis UPS (uninterruptable power supply) information, including
UPS number, vendor, type, IP address, connect port, and SNMP community.
Displays the status of the system control: on, off, or blinking.
In dual MMB mode the roles are switched when the LAN connection to the
master fails, and the slave takes over the role of the master.
Turns on or turns off all server blades.
is automatically performed for inserted server blades or when the basic unit is
powered on. If set to manual, the automatic inventory retrieval is not done.
Configures in detail the power-on/off sequences of the server blades.
Management Agent
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents