Fujitsu PRIMERGY BX900 User Manual page 49

Blade server systems, serverview management blade s1, user interface description
Hide thumbs Also See for PRIMERGY BX900:
Table of Contents

Advertisement

Web User Interface
– On BX900 Remote Management
Supplies an overview of all help texts.
The banner frame is collapsible ( ).
2. Status frame (2)
The status frame consists of a number of graphical or text controls or displays. Taking our example in
we will describe the various elements below, showing the graphical elements in a list and separating them
with ⏐. Viewed from top left to bottom right, the following elements are involved here:
This field displays the overall status of the blade server.
The icon on the left (red) indicates that an error of the type "Critical Error" has occurred in the system.
Such as error must be corrected immediately. The components which are affected are displayed in the
navigation frame (see below). It is possible for more than one error of this type to occur in the system.
The icon in the middle (yellow) indicates that an error of the type "Warning" or "PDA Error" has occurred
in the system. A PDA (Prefailure Detection Analysis) reports problems in hardware components (fans,
CMOS batteries, memory modules and hard disk drives) before these result in a system failure. The
component which is affected is displayed in the navigation frame (see below). It is possible for more than
one error of this type to occur in the system.
The icon on the right (green) indicates that the system is operating without error.
I
If errors of the type "Critical Error" and of the type "Warning" or "PDA Error" have occurred simul-
taneously in the system, the higher-ranking error, i.e. the red icon, is always displayed here.
This button enables you to refresh all the blade server data.
Uptime
Specifies the time since the blade server was started.
⏐ yellow blinking ⏐
CSS:
This field indicates errors of the type "CSS" (Customer Self Service), in other words errors which users
can rectify themselves. The component which is affected is displayed in the navigation frame (see
below).
The yellow icon indicates that an error of the type "Warning" or "PDA Error" has occurred in the system.
When the yellow icon is in the blinking state, it is not a warning but indicates an error of the type "Critical
Error". Detailed information on these error types is provided at the start of this list. The gray icon indicates
that all system components are operating without error.
⏐ red blinking ⏐
Error:
This field indicates errors of the type "Error", in other words errors which cannot be corrected by the user,
but can only be rectified by Customer Service. The component which is affected is displayed in the
navigation frame (see below).
The red icon indicates that an error of the type "Warning" or "PDA Error" has occurred in the system.
When the red icon is in the blinking state, it is not a warning but indicates an error of the type "Critical
Error". Detailed information on these error types is provided at the start of this list. The gray icon indicates
that all system components are operating without error.
System Asset Tag:
Displays the System Asset Tag assigned to the system unit if applied.
ServerView BX900 S1 Management Blade
The Start Page
figure
31,
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents