Server Blade Control Information - Fujitsu PRIMERGY BX900 User Manual

Blade server systems, serverview management blade s1, user interface description
Hide thumbs Also See for PRIMERGY BX900:
Table of Contents

Advertisement

Management Agent

3.3.4.1 Server Blade Control Information

This option enables the user to set the following parameters:
Parameter
Server Power
Set Server Boot Mode
Set Server Blade Host Name
Server LED Control
Server Memory Dump Flag
Server Power On/Off Time Control
Server Power Force Power Off
Enabled
Server Power Force Power Off Control If the "proper" shutdown of the server blade fails, the "forced shutdown"
BIOS Recovery Flash Bit
iRMC Address Configuration
22
Description
Set server power:
(1) on
(2) off
(3) power-cycle
(4) reset
(5) NMI
(6) force off
The boot modes init and inventory are supported by VIOM function. For
details, please refer to the VIOM spec.
Host name of the server blade. Is overwritten with the host name
assigned in the operating system when ServerView agents are used.
Configuration of the LED control at the front of the blade server: blinking
or off.
Indicates the status of the Server Memory Dump Flag (normal or off).
The user can set up a power on/off schedule for server blade.
Controls the "forced" shutdown (termination of processes is not waited
for; these are closed immediately).
is initiated after n minutes.
This option can be selected if the server blade's BIOS has problems or
a flash has failed. After the option has been set, the blade can be started
up "without" the BIOS. It then searches autonomously for a suitable
BIOS on the connected media (floppy, USB stick, CD/DVD) and flashes
it.
Sets up the LAN connection of the iRMC.