Power Consumption Display

5.1
Power Consumption Display
The total power consumption is displayed at the top right in the Status Frame:
Figure 41: Display of the power consumption in the Status Frame
The bar chart shows the following power consumption values. You can display the meaning and exact value as a
tooltip using the mouse:
green
Actual power consumption of the system unit from the PSU outlets (output power consumption)
blue
Maximum power budget used by the system unit from the PSU outlets
yellow
Warning threshold for the input power consumption of the PSUs
red
Configurable input power consumption limitation of the PSUs
black
Highest possible input power consumption of the PSUs
The 2nd line provides information about the secondary output power of the PSUs which is still available for devices
in the system unit (without power consumption of the PSUs), depending on the PSU types and on the power
management settings.
5.2

Control via Tabs

On the Power Management page four tabs are available which are described in detail below:
1. History tab
2. Power Switch tab
3. Input Power Limit tab
4. Consumption tab