AC Wiring Connections

For the MMS1012 model, the AC input and output wiring is performed
in the AC wiring compartment. This compartment is accessed via
the top panel (see Figure 3, Item 8). If the panel cover is installed,
remove the two Phillips screws on the cover to access the AC wiring
compartment and locate the inverter's AC wiring. There is a label
located in the AC access compartment which gives information on
which wires are used for AC input and output. You can also refer to
Table 3 to match the inverter's AC wires to the appropriate AC wire
connection.

Table 3, Wire Color to AC Wire Connection

AC IN
AC OUT
AC Ground
The AC wires inside the AC compartment are #16 AWG with a tem-
perature rating of 105° C. All AC connections should be made using
an approved connector for your application (e.g., split bolt, twist-on
wire connectors, etc.). Ensure the wire connectors used are rated for
the size and number of wires you are connecting.
After connecting the wires together, gently pull on the wires to ensure
they are securely held together. In a proper connection, no bare wire
should be exposed
Info: Per UL certifi cation, non-metallic sheathed cable
(i.e., Romex™) or an SO fl exible cord with listed strain
reliefs are allowed to be used to connect to the inverter;
conduit connections are not allowed.
After all AC wiring in the inverter is complete (and before reattaching
the AC access cover), ensure all connections are correct and secure.

AC Wire Size and Overcurrent Protection

The AC input and output wiring must be sized
electrical safety code requirements
safely handle the inverter's
the proper AC wire sizes, the inverter's AC input (unless you are using
a fl exible cord) and output wires are required to be protected against
overcurrent and have a means to disconnect the AC circuits.
© 2010 Magnum Energy, Inc.
Wire color (label)
Black (HOT IN)
White (NEUT IN)
Red (HOT OUT)
White with black
stripe (NEUT OUT)
Green (GROUND)
.
maximum load current. After determining
2.0 Installation
Wire connection
Hot In
Neutral In
Hot Out
Neutral Out
AC IN and AC OUT Ground
per the NEC and
to ensure the wire's ability to
local
21