Remote Room Sensors; 1.Remote Room Sensor Averaging - Carrier Infinity SYSTXCCITW01 Installation Instructions Manual

Infinity touch control
Hide thumbs Also See for Infinity SYSTXCCITW01:
Table of Contents

Advertisement

Close to or in direct airflow from supply registers.
S
In areas with poor air circulation, such as behind a door or in an alcove.
S
4.3.2.

Remote Room Sensors

A Remote Room Sensor can be used with the Infinity Touch Control to take the
place of the control's internal temperature sensor. This allows the Infinity Touch
Control to be mounted in areas with less than optimal airflow (such as near an
exterior door, window or in a closet). The remote sensor can be wired to the
terminal block connectors labeled S1 and S2 at the control's backplate, or the ZS1
and ZS1C connection at the Damper Control Module. In either case, the Infinity
Touch Control will automatically detect the Remote Room Sensor and ignore its
internal temperature sensor.
4.3.2.1.
Remote Room Sensor Averaging
Typically, one remote sensor is used but, multiple sensors may be used and
averaged in some applications. Averaging requires a special series- - parallel wiring
method with a specific number of sensors. See figure below. It is also important to
note the humidity sensor cannot be remotely located, so do not locate the Infinity
Control in an area where humidity sensing may not be accurate.
6