Exposed to direct light or heat from a lamp, sun, fireplace, or other
S
temperature- - radiating objects which could cause a false reading.
Close to or in direct airflow from supply registers.
S
In areas with poor air circulation, such as behind a door or in an alcove.
S
4.3.2.
Wired Remote Room Sensors
A Remote Room Sensor can be used with the Infinity System Control to take the
place of the control's internal temperature sensor. This allows the Infinity System
Control to be mounted in areas with less than optimal airflow (such as near an
exterior door, window or in a closet). The remote sensor can be wired to the
terminal block connectors labeled S1 and S2 at the control's backplate, or the ZS1
and ZS1C connection at the Damper Control Module. In either case, the Infinity
System Control will automatically detect the Remote Room Sensor and ignore its
internal temperature sensor.
NOTE: Humidity sensing will occur ONLY at the Infinity System Control. The
wired Remote Room Sensor does NOT have humidity sensing capability.
4.3.2.1.
Wired Remote Room Sensor Averaging
Typically, one wired remote sensor is used but, multiple wired sensors may be used
and averaged in some applications. Averaging requires a special series- - parallel
wiring method with a specific number of sensors. See figure below. It is also
important to note the humidity sensor cannot be remotely located, so do not locate
the Infinity System Control in an area where humidity sensing may not be accurate.