Troubleshooting Guide - HearthStone Mansfield 8011 Owner's Manual

Wood stove
Table of Contents

Advertisement

T
ROUBLESHOOTING
PROBLEM
STOVE SMOKES
BACK-PUFFING OR
GAS EXPLOSIONS
UNCONTROLLED
OR SHORT BURN
INSUFFICIENT HEAT
BLISTERING OF
ENAMEL CASTING
HearthStone Quality Home Heating Products Inc ®
G
UIDE
POSSIBLE CAUSE
Operating Technique
Cold Chimney
Blocked Chimney
Oversized Chimney
Undersized Chimney
Chimney Too Short
Air Infiltration Into The
Chimney
More Than One Appliance
Connected to the Flue
Operating Technique
Extra Low Burn Rate
Chimney Down-draft
Excessive Ash Build-up
Unsealed or Open Door
Excessive Draft
Deteriorated Cement Seals
Extra Long Chimney
Oversized Chimney
High Winds or Hilltop
Location:
Excessive Draft
Poor Quality or Green
Wood
Low Burn Rate
Air Insulated Chimney
Cold Exterior Chimney
Leaky Stovepipe or
Chimney
Too Much Heat Loss From
House
Operating Technique
Excessive Draft
SOLUTIONS
Fully open the primary air control one minute before opening doors.
Preheat the chimney when first starting a fire.
Examine the chimney and stovepipe for blockage or creosote
accumulations.
Reline the chimney to the appropriate diameter
Install a draft inducer or replace the chimney.
Lengthen the chimney.
Seal chimney connections and openings in clean-out doors.
Disconnect all other appliances and seal openings.
Fully open the primary air control one minute before opening the
door and keep it fully open for a few minutes after reloading.
Burn the stove at a higher burn rate.
Install a chimney cap.
Empty ash pan more frequently.
Close the door tightly or replace the gaskets.
Check the installation. Operate at LOW BURN. Install stovepipe
damper.
Reseal the stove with furnace cement.
Shorten the chimney. Install stovepipe damper.
Reline the chimney to the proper diameter.
Install a chimney cap.
Draft in excess of 0.1 wc should be corrected with a stovepipe
damper
Use only air-dried wood, preferably dried at least one year.
Operate the stove at a higher burn rate.
Replace with a pre-fabricated insulated chimney system or a
properly sized masonry chimney.
Reline or insulate the chimney.
Check the installation.
Caulk windows, seal openings in home.
Do not over-fire the stove. Monitor stove temperatures. Use
seasoned wood only.
Check the DRAFT. (See page 10) A damper may be required.
Operate the stove at a LOW BURN range.
21
Mansfield Model 8011