Terminology; Display During Microbubble (Mb) No-Stop Phase; Display During Level Stop Phase - Uwatec Aladin PRIME Operating Manual

Table of Contents

Advertisement

TEC Diving with microbubble level (MB)

2 Terminology

This chapter will exclusively deal with terminology and display features used while diving with MB levels.
All other features are described in chapter III (->15).

2.1 Display during microbubble (MB) no-stop phase

MB no-stop time
Remaining time at a
respective depth allowing
ascent without level stop.
DEPTH
DEPTH
DIVE
DIVE TIME
TIME
NO
NO ST
NO STOP
OP
CNS O
%
2
Nitrogen
2 x
loading bar
MB level
relative to LO
activated
->24
Level L2
is active
35.7m
(Max. depth
> MB level active
> No-stop time relative to L0
> Temperature
> (Max. depth)...
Whereas the quantitative information relative to L0 can be seen by pressing the right button,
qualitative information is always visible on the display in form of the nitrogen loading bar. In par-
ticular, when the L0 no-stop time is less than three minutes, the nitrogen bar will flash ->24. This
will help you avoid entering inadvertently into decompression.

2.2 Display during level stop phase

Total ascent time
including level stops
DEPTH
DEPTH
DIVE
DIVE TIME
TIME
STOP
STOP
CNS O
%
2
S S
L L
O O
W W
Level stop
Nitrogen
depth
loading bar
The deepest level
relative to LO
stop is displayed.
->24
Level stop duration
The duration of a level stop
at a given level stop depth
is displayed.
(Max. depth
> MB level active
> No-stop time or deco information relative to L0
> Temperature
> (Max. depth)...
V UWATEC
®
Aladin
®
dive computers
MB no-stop phase
Dive phase during which surfacing is
possible without MB level stop.
Time
16 min Dive time
Maximum depth
>) Temperature
and time of day
Time
35.7m
117ft
MB no-stop phase
>) Temperature
and time of day
9min
MB no-stop time
Current depth
Total ascent time
9m/30ft
Level stop phase
To complete the dive without being
reduced to a lower MB level all requested
level stops must be observed.
Level stop phase
(14 min)
3m/10ft
6m/20ft
Lowest level
stop depth
3 min
Level stop duration